Controller Input and PLC Output
#
bit
15
bit
14
bit
13
bit
12
bit
11
bit
10
bit
9
bit
8
bit
7
bit
6
bit
5
bit
4
bit
3
bit
2
bit
1
bit
0
0
Sensor 1 Command Register
1
Sensor 2 Command Register
2
RLC
RBL
Maximum Brightness Limit
Minimum Brightness Limit
3
S2A S2BO
Sensor 2 Brightness Override
Value
S1A
S1BO
Sensor 1 Brightness Override
Value
4
Guide command register
5
Guide point offset register
6
EN
Motor speed percentage register
EN
Motor acceleration percentage register
7
Reserved for future
Sensor Command Register
The bits in the command register are organized as follow:
Bit #
Value
Label
Description
0-1
0, 2 or 3
Sensor orientation
0: set sensor orientation to be right sensor
2: set sensor orientation to be left sensor
3: set sensor orientation to be center sensor
2
0/1
Sensing mode
0: set the sensing mode to be edge mode
1: set the sensing mode to be contrast mode
3-5
0-7
Analog mode
0: Analog output is disabled.
1: Analog output is enabled and zero scale voltage/current is output.
Note: This mode can be used during calibration while connecting the
controller to a third-party controller that requires calibration. During the
calibration, this mode can be selected to calibrate for zero scale output.
2: Analog output is enabled and full scale voltage/current is output.
Note: This mode can be used during calibration while connecting the
controller to a third-party controller that requires calibration. During the
calibration, this mode can be selected to calibrate for full scale output.
3: Analog output is enabled and the analog output corresponds to the left
edge position.
Content subject to change without notice
SCU5: Sensor and Web Guide Controller User Manual v 3.6| Page 54
Copyright © 2021 Roll-2-Roll Technologies LLC