![Argus PiCUS TMS 3 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/argus/picus-tms-3/picus-tms-3_applications-manual_2969446018.webp)
PiCUS TMS 3 manual
18
www.argus-electronic.de
Technical data
Property
Value
General characteristics
colour
grey
weight
73 g
dimensions
61 mm x 41 mm x 20 mm
protection
Protected against dust & permanent submerging in water
mounting
1 self-tapping, fillister head screw
min. lifetime
5 years
Battery
Battery capacity
250 mAh
Battery runtime
> 14 days
Charging
Wireless, directly in the TMS-case
Maximum charge current
approx. 200 mA
Charge duration
approx. 2 h
Recommended charging temperature
5
– 35 °C (ambient temperature)
Maximum temperature range for charging
0
– 40 °C (ambient temperature)
Measurement
Accuracy tilt measurement
0,03°
Resolution tilt measurement
0,005°
Measurement interval
0,05 s (20 Hz)
Type of tilt measurement
3D-measurement
Sensor orientation
arbitrary
Accuracy temperature measurement
1 °C
Temperature range
-20
– +50 °C
Accuracy battery voltage measurement
0,05 V
Memory
Memory type
Internal Flash memory
Memory size
256 MB
Memory runtime
20 days
Communication
Standby- and measuring mode
Bluetooth Version 5.0 BLE mode
Data download
Bluetooth Version 5.0 High Speed mode
max. transmission rate
approx. 200 kBps