11 Resistance symmetry (RSym)
ARGUS Copper Box
61
When a wire type is selected, the line
length is calculated from the specific
resistance.
Display:
Example measurements:
The resistances Ra and Rb are very
close together. The relative deviation is
below 1 %. The wires are extremely
homogeneous.
The resistances Ra and Rb deviate
greatly. The relative deviation is consider-
ably above the recommended 1 %. The
wires are extremely asymmetrical.
- Rs (sum of loop resistances) (in Ω)
- Ra (resistance of Tip-wire) (in Ω)
- Rb (resistance of Ring-wire) (in Ω)
- Line length in km
- Specific resistance of the selected wire
type