![Argus 165 Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/argus/165/165_manual_2969439041.webp)
7 Operation on xDSL accesses
41
ARGUS 165
7 Operation on xDSL accesses
ARGUS supports the following DSL interfaces: ADSL, VDSL, SHDSL
ARGUS supports the following access modes on xDSL accesses:
The individual DSL tests record and store data (e.g. traces of IP data). It is the
user's responsibility to comply with the applicable legal requirements.
The line may not carry a DC voltage greater than 200 V DC and should be free of
AC voltage components.
In principle, the operating temperature range set out in "Technical data" (see
page 17) applies for SHDSL operation. For ambient temperatures just below
+50 °C, extended operation in high-performance modes can trigger the
temperature dependent ARGUS protection functions described in the safety
information (see page 12).
xTU-R
Terminal device mode (xDSL transceiver unit) see page 54.
ARGUS is connected to the xDSL access (in front of or behind the
splitter). ARGUS replaces the modem and PC.
xTU-R bridge
Bridge mode (xDSL transceiver unit bridge) see page 80.
ARGUS is connected to the xDSL access and the PC.
ARGUS replaces the xDSL modem (for SHDSL only ATM and EFM).
xTU-R router
Router mode (xDSL transceiver unit router) see page 82.
ARGUS is connected to the xDSL access and the PC.
ARGUS replaces the xDSL modem and router (for SHDSL only ATM
and EFM).
STU-C
(STU-C: SHDSL Transceiver Unit-Central Office).
ARGUS simulates the central office side (DSLAM).
Содержание 165
Страница 26: ...4 Quick start guide 26 ARGUS 165 ...
Страница 37: ...5 Configuring accesses ARGUS 165 37 Test parameter settings are described starting on page 124 ...
Страница 170: ...15 IP tests 170 ARGUS 165 ...
Страница 235: ...19 Parallel tests ARGUS 165 235 ...
Страница 284: ...23 Copper tests 284 ARGUS 165 ...