17 VoIP tests
186
ARGUS 165
Volume control settings:
VoIP overview display (for transmitted and
received packets including assessment)
<External>
Headset mode
<Internal>
Earpiece mode
<OK>
Adopts settings
-
-
-
-
-
Status of MOS value (FAR-MOS/MOS)
Jitter in ms
RTP loss rate
VLAN (prio) in hexadecimal
TOS (hex) in hexadecimal
The FAR-MOS value is only
displayed when the remote station
supports RTCP.
Displays MOS information:
-
-
-
-
-
Current MOS
Average MOS
Min./max. MOS value
Ideal MOS (possible MOS without
interference, codec-dependent)
Current and average
R-factor according to ITU-T G.107
Back to previous display.
<Detail>
Continued on
next page