background image

P 1

01OSBP0603-V1

6x3 Pent Shed

2mm Drill bit

x2

Winter = High Moisture = Expansion

Summer = Low Moisture = Contraction

All building’s should be 

erected by two adults

For ease of assembly, you 

MUST pilot drill all screw 

holes and ensure all screw 

For assistance please contact customer care on: 01636 880514

Mercia Garden Products Limited, 

Sutton On Trent, 

Newark, 

Nottinghamshire, 

NG23 6QN

www.merciagardenproducts.co.uk

CAUTION

Every effort has been made during the 

manufacturing process to eliminate the 

prospect of splinters on rough surfaces of the 

timber.  You are strongly advised to wear gloves 

when working with or handling rough sawn 

timer.

**Protim Aquatan T5 (621)**

Protim Aquatan* T5 is a coloured, water-based concentrate which is diluted with water to make a solution 

for application to unseasoned timber. Protim Aquatan T5 treated wood is not protected against wood 

destroying insects or wood decaying fungi. Further preservative treatment is required to protect against 

these organisms.

Contains: Boric Acid, Sodium Hydroxide 32% solution, aqueous mixture of sodium dioctyl sulphosuccinate & 

alcohols: 2,4,6-Trichlorophenol.

Hazard Statements:

H315: Causes skin irritation.

H319: Causes serious eye irritation.

H412: Harmful to aquatic life.

Wear gloves when handling freshly treated wood. 

Avoid breathing dust when cutting treated or untreated wood. 

Dispose of off-cuts responsibly – do not burn.

IF SKIN IRRITATION OCCURS: Get medical advice/attention.

IF IN EYES: Rinse cautiously with water for several minuets. Remove contact lenses, and continue rinsing. If 

the irritation persists: Get medical advice/attention.

DO NOT INGEST.

Please retain product label and instructions for future reference

             

P 1

General Instructions

BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY 

- Check the pack and make sure you have all the parts listed. 

- When you are ready to start, make sure you have the right tools at hand (not supplied) 

including  a Phillips screwdriver, Stanley knife, wood saw, step ladder and drill with 2mm 

bit.

- Ensure there is plenty of space and a clean dry area for assembly. 

TIMBER

As with all natural materials, timber can be affected during various weather conditions. 

For the duration of heavy or extended periods of rain, swelling of the wood panels may 

occur. Warping of the wood may also occur during excessive dry spells due to an interior 

moisture loss. Unfortunately, these processes cannot be avoided but can be helped. It is 

suggested that the outdoor building is sprayed with water during extended periods of 

warm sunshine and sheltered as much as possible during rain or snow. 

Our buildings are pre treated with a water based treatment**; this only helps to protect 

the product during transit and for upto 3 months against mould.  To validate your 

guarantee and ensure longevity of the product, it is ESSENTIAL the building is treated 

with a wood preserver within the first three months of assembly and thereafter in 

accordance with the manufactures recommendations.  Care must be taken to ensure 

the product is placed on a suitable base.

BUILDING A BASE

When thinking about where the building and base is going to be constructed: 

Ensure that there will be access to all sides for maintenance work and annual 

treatment.

Ensure the base is level and is built on firm ground, to prevent distortion.  Refer to 

diagrams for the base dimensions,  The base should be slightly smaller than the external 

measurement of the building, i.e. The cladding should overlap the base, creating a run 

off for water. It is also recommended that the floor be at least 25mm above the 

surrounding ground level to avoid flooding.

TYPES OF BASE

- Concrete 75mm laid on top of 75mm hard-core.

- Slabs laid on 50mm of sharp sand.

Whilst all products manufactured  are made to the highest standards of Safety and in 

the case of childrens products independently tested to EN71 level, we cannot accept 

responsibility for your safety whilst erecting or using this product.

Refer to the instructions pages for you specific product code

Содержание 01OSBP0603-V1

Страница 1: ...t supplied including a Phillips screwdriver Stanley knife wood saw step ladder and drill with 2mm bit Ensure there is plenty of space and a clean dry area for assembly TIMBER As with all natural materials timber can be affected during various weather conditions For the duration of heavy or extended periods of rain swelling of the wood panels may occur Warping of the wood may also occur during exce...

Страница 2: ...N Door Gable Plain Gable Front Panel Rear Panel Door Floor Roof Sheet Gable Tops T Hinge QTY 2 Pad Bolt Felt 10 11 12 13 14 15 16 17 18 Eave Framing 1828mm Front Corner Trim 1882mm QTY 2 Rear Corner Trim 2082mm QTY 2 Rear Fascia 1882mm Side Fascia 1035mm QTY 2 Bolt Block 160mm Remove transportation blocks from the bottom of each panel before beginning assembly Each Panel should have two Pre Assemb...

Страница 3: ...e same method shown in Step 2 Step 4 Secure the gable tops onto the plain and door gables ensuring the panels are flush Fix in place using 2x30mm screws per side Step 5 fix the eave framing to the edge of the roof sheet using 4x30mm screws Place roof into position ensuring the eave fits butt against the front panel cladding Secure using 10x30mm screws as shown in the diagram 9x50mm Screws Pre dril...

Страница 4: ...hang around the sides Felt tacks 100 x Felt Tacks Step 9 Use 3x30mm screws to fix each cover trim to the corners of the building as shown in diagram 12x30mm Screws Pre drill hole 30mm screw 17 Step 8 Fix the hinges to the door with 8 x30mm screws ensuring they are located into the door framing Attach the door to the gable using 6x30mm screws Fit the bolt block to the door using 2x30mm screws screw...

Страница 5: ... building has been assembled P 5 Please retain product label and instructions for future reference Step 10 Fit the fascia boards to the sides and back of the building using 3x40mm screws per board as shown in the diagram 9x40mm Screws Pre drill hole 40mm screw 14 14 13 ...

Отзывы: