Subject to change_SD3EX-B2_SD3EX-C2_14067_1en_06/2022
Page 12
www.argo-hytos.com
Ordering code
Bx
H
SD3EX - / /
-
x
xxx
Ax
xx
B
xxxxx
x
1
2
3
4
5
6
7
8
9
10
1
Screw-in spool type, solenoid operated directional control valve, designed for potentially explosive atmospheres
Threaded screw-in cavity type
B2
cavity B2(C-10-2) with thread 7/8-14 UNF
C2
cavity C2 (C-12-2) with thread 1-1/16-12 UN
High performance
Valve connection
2O2
2L2
Spool connection (according to connection table)
DC voltage
01200
12 V DC / 0.75 A
02400
24 V DC / 0.39 A
04800
48 V DC / 0.19 A
11000
110 V DC / 0.094 A
AC voltage 50/60 Hz
11050
110 V AC / 0.112 A
23050
230 V AC / 0.052 A
Temperature class - coil nominal input power
A4
coil supply power 10 W, temperature class T4
A6
coil supply power 10 W, temperature class T5, T6
Cable length
without designation
(only DC version)
without cable
3
(versions AC and DC)
3 m
8
(versions AC and DC)
8 m
Manual override
without designation
standard
M7
detent assembly
M9
without manual override
Seals
without designation
NBR
Surface protection by galvanizing
B
520 h in NSS according to ISO 9227
Valve certification
without designation
ATEX, IECEx
A
IECEx for Australia and New Zealand
E
EAC for EAEU states*
*EAEU= Eurasian Economic Union, certificate
according to TR TS 012/2011 valid for the Russian
Federation, Belarus, Armenia, Kazakhstan and
Kyrgyzstan.
11
2
3
7
4
6
8
10
5
11
9
Содержание SD3EX-B2
Страница 3: ...Subject to change_SD3EX B2_SD3EX C2_14067_1en_06 2022 Page 3 www argo hytos com ...
Страница 4: ...Subject to change_SD3EX B2_SD3EX C2_14067_1en_06 2022 Page 4 www argo hytos com ...
Страница 23: ...Návod k použití_SD3EX B2_SD3EX C2_14067_1cz_06 2022 Strana 2 www argo hytos com Prohlášení o shodě ...
Страница 24: ...Návod k použití_SD3EX B2_SD3EX C2_14067_1cz_06 2022 Strana 3 www argo hytos com ...
Страница 25: ...Návod k použití_SD3EX B2_SD3EX C2_14067_1cz_06 2022 Strana 4 www argo hytos com ...