IDENTIFICATION CODES 

 

Each pump is supplied with the serial and model abbreviation and the serial number on the rating plate, which is riveted onto 
the support side. Check these data upon receiving the goods. Any discrepancy between the order and the delivery must be 
communicated immediately.  

In  order  to  be  able  to  trace  data  and  information,  the  abbreviation,  model  and  serial  number  of  the  pump  must  be 
quoted in all correspondence

 
 
 

 

GENERAL NOTES 

 

"ZRM" pumps are designed and built for the transfer of liquid chemical products having a specific weight, viscosity, temperature 
and stability of state appropriate for use with centrifugal pumps in a fixed installation, from a tank at a lower level to a  tank or  a 
pipe  to  a  higher  level.  The  characteristics  of  the  liquid  (pressure,  temperature,  chemical  reactivity,  specific  weight,  viscosity, 
vapour  tension)  and  the  ambient  atmosphere  must  be  compatible  with  the  characteristics  of  the  pump  and  are  defined  upon 
ordering. 
 
The pump's performance (capacity, head, rpm) is defined upon ordering and specified on the identification plate. 
 
“ZMR” pumps are not self priming. 

“ZMR” pumps cannot run dry. 
 
The type of the solid particles contained in the pumped liquid depend on the mechanical seal; the presence of fibrous, adhesive 

or abrasive bodies is not allowed. 

 
Exame of the solid particles: 
 

 

 

 

 

Mech.seal  SF1-TS5 

Mech.seal   TS6 

Mech.seal MSFA 

– MTSC - MTSD 

 

max quantity in weight % 

  3 

1

 3 (a) - 1

 5 (b) 

  11 

 

max dimension in mm 

0.1 

  0.6 

0.1

 0.6 (a) - 1

 2 (b) 

0.1 

  0.8 

 

max hardness Mohs index 

  2 

  6 

  2 

 

 
Clockwise rotation seen from the motor side. 
 
Make sure that the chemical and physical characteristics of the liquid have been carefully evaluated for pump suitability. 
 
The  specific  weight  which  can  be  pumped  at  a  temperature  of 

25°C

  (both  of  the  liquid  and  the  ambient)  depends  upon  the 

diameter of the impeller (shown on the identification plate) and the installed motor power (shown on the motor plate) and has 
to be defined upon ordering. 

 
The level of kinematic viscosity must not exceed 20 cSt so as not to significantly modify the pump's performance. Higher values 

up to a maximum of 250 cSt are possible provided that the pump is equipped with suitable impeller and motor to be defined 
upon ordering. 

 
The  maximum  continuous  working  temperature  referred  to  water  depends  on  the  choice  of  materials  (specified  on  the 
identification plate): 

80°C (176°F) 

 

 

 

version WR 

  

 

 

            110°C (230°F) 

 

 

 

version  GF 

 
variations may occur, depending on operating pressure 
The ambient temperature interval is related to the choice of materials (specified on the identification plate): 
 
 

 

 

        0 ÷ 40 °C (14 ÷ 104 °F) 

 

  

version WR 

 

 

 

 

     -20 ÷ 40 °C (-4 ÷ 104 °F) 

 

  

version  GF 

SERIAL NUMBER 

 

RANGE 

MODEL 

Содержание ZMR 02.30

Страница 1: ... MTS5 2 2 3 N P S N integral 02 30 03 35 armoured TS8 MTS6 3 5 BS5 MTS7 4 5 Atex chose BS6 MTS8 1 DISASSEMBLING SEQUENCE 2 1 1 LEGEND 3 2 IDENTIFICATION CODES 4 3 GENERAL NOTES 4 4 OPERATING PRINCIPLE 5 5 MOTOR 5 6 PRESSURE SWITCH TO PREVENT DRY RUNNING 6 7 INSTRUCTION ON INSTALLATION AND USE 6 7 1 TRANSPORT 6 7 2 INSTALLATION 6 7 3 START UP 7 7 4 USE 8 7 5 SHUTDOWN 8 8 MAINTENANCE 8 8 1 DISMANTLI...

Страница 2: ...2 1 DISASSEMBLING SEQUENCE ...

Страница 3: ... 304 1 42 932 1 Seeger ring PP 1 43 185 Packing ring PP 1 44 412 6 OR drain plug OR 2050 V FKM E EPDM K FFKM 1 46 493 Dividing plate PP 1 47 932 2 Seeger ring STEEL 1 100 722 3 Outlet flange FF PP 1 102 722 4 Inlet flange FF PP 1 Mechanical seal 6 134 1 Intermediate casing WR PP GF E CTFE GX E CTFE 1 6 A 134 2 Intermediate casing BS WR PP GF E CTFE GX E CTFE 1 20 412 3 OR fixed seal OR 3200 V FKM ...

Страница 4: ...cal seal the presence of fibrous adhesive or abrasive bodies is not allowed Exame of the solid particles Mech seal SF1 TS5 Mech seal TS6 Mech seal MSFA MTSC MTSD max quantity in weight 1 3 1 3 a 1 5 b 1 11 max dimension in mm 0 1 0 6 0 1 0 6 a 1 2 b 0 1 0 8 max hardness Mohs index 1 2 3 6 1 2 Clockwise rotation seen from the motor side Make sure that the chemical and physical characteristics of th...

Страница 5: ...e motor bearings THE MECHANICAL SEAL placed at the point where the shaft enters the pump body to drive the impeller is made up of two main section a fixed section inserted in the pump body and a rotating section integral with the shaft The tight contact between these two parts guarantees a seal against leakage whether the pump is rotating or not The rubbing action that occurs between these two par...

Страница 6: ...d remote control switch In order to obviate any pulsations of the pressure switch it is necessary to set its setpoint to a pressure value equal to 65 of the working pressure It is obvious that this device cannot be used to control working pressure On start up the pressure switch contact must be by passed for a sufficient time to allow pressure to build up in the system In case of automatic start u...

Страница 7: ...nmental conditions in accordance with the IP protection of the motor install a drainage pit to collect any liquid overflow from the base drainage channel due to normal maintenance work leave enough free space around the pump for a person to move leave free space above the pump for lifting operations highlight the presence of aggressive liquids with coloured tags following the local safety regulati...

Страница 8: ...id and the operating conditions on the rotating parts of the pump clean or replace as necessary make periodic inspections 3 to 5 months depending on the type of liquid and the operating conditions on the functionality of the motor control system efficiency must be guaranteed make periodic inspections 2 to 30 days depending on the type of liquid and the operating conditions of the in line and foot ...

Страница 9: ...e a right hand thread Bolt torque setting M4 M6 M8 M10 M12 M16 M20 M24 reduce by 25 on plastic parts Nm 4 14 24 48 60 75 120 175 all the tasks must be performed under supervision of qualified personnel seal with new o rings assemble the pump by following the procedure set out in the LEGEND column in the reverse order clean out the motor shaft from any trace of dust and or grease mount the pump sha...

Страница 10: ... far as the non synchronous motor is concerned and may cause injury to hands if working on an open pump Risks may also arise due to the nature of the liquids pumped It is therefore of utmost importance to closely follow all the instructions contained in this manual so as to eliminate the causes that may lead to pump failure and the consequent leakage of liquid dangerous for both personnel and the ...

Страница 11: ...awareness of possible damage to parts due to abrasion or shocks during handling know how of required bolt and screw tightening required on different materials such as plastics and metals use of precision measuring instruments opening and closing of the pump body removal and replacement of rotating parts 9 4 WASTE DISPOSAL Materials separate plastic from metal parts Dispose of by authorized compani...

Страница 12: ...y than expected 23 specific weight of liquid is greater than expected 24 impurities inside pump create abnormal wear 25 electric motor supply voltage is not rated voltage Pump vibrates and is noisy see 23 26 operates at full capacity no head 27 pump or pipes inadequately fixed 28 eccentric impeller operation because of worn bushes 28 support bearing without grease Pump s internal parts wear out to...

Страница 13: ... 16 x 4 16 x 4 16 x 4 16 x 4 16 x 4 16 x 4 d x z JIS 19 x 4 19 x 4 19 x 4 19 x 4 19 x 4 19 x 4 Dimensions in mm for connections type Y see pag 1 IDENTIFICATION CODE KM KA MOTOR IEC 60 Hz Model ZMR 07 11 07 14 11 15 11 23 17 25 03 35 IEC frame 80A 80B 90S 80B 90S 90L 90S 90L 100 90L 100 112 112 a1 67 67 67 67 67 67 L 393 413 393 413 438 413 438 486 438 486 495 495 Q 75 75 75 75 75 75 h1 80 90 80 90...

Страница 14: ... 32 13 32 g 5 7 16 5 29 32 5 29 32 7 1 32 5 29 32 7 1 32 7 1 32 7 1 32 7 1 32 L3 7 9 32 7 9 32 8 1 16 7 9 32 8 1 16 8 1 16 8 1 16 8 1 16 B2 9 9 3 4 12 9 3 4 12 12 12 12 s2 9 16 9 16 9 16 9 16 9 16 9 16 L1 9 21 32 9 21 32 10 3 16 9 21 32 10 3 16 10 3 16 10 3 16 10 3 16 B3 12 1 8 12 1 8 14 1 8 12 1 8 14 1 8 14 1 8 14 1 8 14 1 8 h3 1 9 16 1 9 16 1 9 16 1 9 16 1 9 16 1 9 16 KM ISO 3 15 16 3 15 16 3 15...

Страница 15: ...R GF WR GF WR GF WR GF WR GF Power IEC 60 Hz KW 0 75 1 1 1 5 1 1 1 5 2 2 1 5 2 2 3 2 2 3 4 4 Motor frame IEC 80A 80B 90S 80B 90S 90L 90S 90L 100L 90L 100L 112 112 power NEMA 60 Hz HP 1 1 1 2 2 1 1 2 2 3 2 3 5 3 5 5 5 Motor frame NEMA 56 56 145 143 145 182 145 182 184 182 184 184 184 Pump weight No motor Kg 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 Lb 6 7 8 9 6 7 8 9 6...

Страница 16: ...16 ...

Страница 17: ...17 ...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...ce Tel 030 3507025 Web www argal it E mail argal argal it The INSTRUCTION MANUAL must be delivered to the pump user who takes diligent note of it fills in data for Maintenance Department page 1 keeps the file for subsequent reference Possible modifications do not imply updating of the existing manuals Copyright 2018 ARGAL S r l Draw and text total or partial duplication is prohibited REV 10 10 201...

Отзывы: