background image

User’s Manual –

 A

REBO

S Domestic waterworks 1000 W 

 

 
 

property damage. 

 

Lay suction line always rising. If the suction height is more than 23 ft (7 m), a suitable suction 

hose must be installed. 

5.3 Connect pressure line 

 

The pressure line conveys the liquid to be conveyed from the pump to the extraction point. 

 

Screw the pressure line to the discharge nozzle (water outlet) (internal thread). Make sure 

that the thread is not overtightened and damaged. Use appropriate sealants (e.g., O-rings, 
gaskets, sealing strip, etc.). Check the connection for leaks. Leaky connections will cause 
malfunction and can cause property damage. 

 

Make sure that the pressure line is not loaded with its weight on the pump body. Attach 

these as needed. 

 

In case of permanent installation (e.g. domestic water supply) it is recommended to connect 

the device to the pipe network with elastic hose lines to reduce noise and vibrations. 

 

The pressure pipes or hoses connected to the pressure side should be as short as possible, as 

straight as possible, not bent, and not half rolled up. The diameter should be as large as 
possible. 

5.4 Fill the pump 

 

Use a suction line with a check valve, which prevents emptying of the suction line when filling 

or stopping the pump. 

 

Remove the locking screw on the filler neck. 

 

Fill the pump via the filler neck with water until it overflows. 

 

Screw the locking screw onto the filler neck. 

6.

 

Operation 

 

The pumps are not self-priming pumps. Therefore, the intake hose must first be equipped as 

described below: 
1.

 

Check valve with filter; This ensures that after switching off the pump, the hose and the 
pump do not run dry. This part of the hose keeps the pumped water back. 

2.

 

hose connection with coupling nut; this hose end is connected to the front of the pump. 

3.

 

Both accessories must be securely fastened to the hose with hose clamps. 

 

Before connecting the hose to the pump, it is best to fill it with water. Then you can connect 

the three-way tap or another 1 in (25 mm) connection to the outlet of the pump. 

 

Afterwards you have to fill the pump housing with water through the opening of the 

integrated filter and close it again. 

 

When commissioning for the first time, make sure that the pump housing is completely 

vented 

 i.e. filled with water. If this venting is omitted, the pump does not suck in the 

pumped liquid. It is highly recommended, but not urgently necessary, in addition to deaerate 
the intake pipe or to fill it with water. 

 

If both the pump housing and the hose are filled with water, you can turn on the pump with 

the ON/OFF switch. The pump immediately starts pumping water. 
-

 

Tilt the ON/OFF switch to position "I" to switch on the pump. 

-

 

Tilt the ON/OFF switch to position "O" to switch off the pump. 

 

When the pump is turned off again, the water remains in the pump housing and in the hose. 

The next time the pump is turned on, it pumps water immediately. If the check valve has not 
been fitted or if the valve and hose are not properly connected (hose clamp!), the pump may 
run dry again and must be refilled to function properly. 

 

The pump must not work when the inflow is closed. 

Содержание AR-HE-HWW1000

Страница 1: ...User s Manual AREBOS Domestic waterworks 1000 W 1 Domestic waterworks 1000 W AR HE HWW1000 User s Manual Please follow all security measures in this user s manual to ensure a secure use...

Страница 2: ...ns 6 5 Assembly 7 5 1 General 7 5 2 Connect suction line 7 5 3 Connect pressure line 8 5 4 Fill the pump 8 6 Operation 8 7 Troubleshooting 9 8 Cleaning maintenance and storage 13 8 1 General cleaning...

Страница 3: ...iance To install the unit safely and correctly please read the operating instructions before you start Check the unit for any damage that may have occurred during transport Immediately report any dama...

Страница 4: ...n using the domestic waterworks can lead to serious injuries This device is not intended to be used by children and persons with reduced physical mental or psychological abilities and by persons witho...

Страница 5: ...vice and extension cable in a technically perfect condition Damaged devices must not be operated Never carry the pump by the cable The power supply must be in accordance with the specifications given...

Страница 6: ...er components aggressive corrosive explosive or gassing chemicals or liquids water and food or drink liquids above 95 F 35 C 3 Function The pumps have a maintenance free motor with thermal overload pr...

Страница 7: ...essure 5 2 Connect suction line Select the length of the suction line so that the domestic waterworks cannot run dry The suction line must always be at least 11 8 in 30 cm below the water surface The...

Страница 8: ...e the intake hose must first be equipped as described below 1 Check valve with filter This ensures that after switching off the pump the hose and the pump do not run dry This part of the hose keeps th...

Страница 9: ...Suction line not immersed deep enough in the medium Fill the pump with water Check the recommended and used parts and components of the pump e g the connection of the suction hose the connection of th...

Страница 10: ...tion line Clean the suction valve and the strainer Check suction height and discharge head Open the pressure side cutoff taps nozzles etc Have the seal replaced by an authorized specialist Repair or r...

Страница 11: ...nto the intake pipe Contact customer service Check and make sure that a the suction line and all connections are tight b the inlet of the intake pipe including check valve is immersed in the pumped li...

Страница 12: ...ng so open a load in the pressure line e g water faucet to prevent the system from being pressurized Check and make sure that a the suction line and all connections are tight b the inlet of the suctio...

Страница 13: ...asket if necessary Install check valve 8 3 Eliminate blockages If you pump contaminated fluids without an aspiration filter pre filter despite explicit reference not to do so the device may become clo...

Страница 14: ...e pump with clean water Briefly open the screwcap of the metal hose on the boiler and allow the remaining water to drain off Remove suction and discharge lines from the unit For recommissioning the pu...

Страница 15: ...e symbol of the crossed out dustbin on a Waste electrical or electronic equipment indicates that it must not be disposed of with household waste at the end of its life Collection points for waste elec...

Страница 16: ...of conformity will lose its validity Directives This device complies with the following EU EC directives 2014 30 EU EMC Directive 2014 35 EU Low Voltage Directive 2011 65 EU RoHS Directive 2014 68 EU...