Страница 1: ...4 Mini Heater User and Service manual...

Страница 2: ...ge of the applicable regulations and standards as well as the necessary competence in emission prevention and recovery of fluorinated greenhouse gases and handling safety the relevant type and size of...

Страница 3: ...and attentively follow the instructions in implementation and maintenance The installer is responsible for the installation of the product and should follow all the instructions of the manufacturer a...

Страница 4: ...d because of being frozen in such case your warranty will be lost Please always cut the power supply if you want to open the cabinet to reach inside the heat pump because there is high voltage electri...

Страница 5: ...ed pool volume with pool cover m 0 10 5 16 10 20 Advised water flux m3 h 2 2 2 5 3 2 Water Pressure Drop KPa 4 2 5 3 Condenser Titanium exchanger in PVC Water pipe in out mm 32 or 38mm Fan Speed RPM 2...

Страница 6: ...3 Installation and connection Attention Item mm A B C D E F G AP025miniR3 90 4 130 50 375 310 300 363 5 AP045miniR3 AP060miniR3 116 5 200 50 460 434 365 432 5...

Страница 7: ...ed see drawing below Please consult your installer for installation with an indoor pool Installation in a windy location does not present any problem at all unlike the situation with a gas heater incl...

Страница 8: ...ses clamp will be provided by the user or the installer 3 4 Electrical connection Before connecting the unit verify that the supply voltage matches the operating voltage of the heat pump The RCD plug...

Страница 9: ...turn off the filter pump the unit should also turn off automatically Depending on the initial temperature of the water in the swimming pool and the air temperature it may take several days to heat the...

Страница 10: ...4 1 Swimming pool heat pump wiring diagram AP025miniR3 4 2 Swimming pool heat pump wiring diagram AP045miniR3 AP060miniR3...

Страница 11: ...quired to protect you against short circuits inside the unit Bonding is also required Disconnect A disconnect means circuit breaker fused or un fused switch should be located within sight of and readi...

Страница 12: ...p 5 3 Set the water temperature Press or directly to adjust water temperature range 10 42 Press to save the setting then exit 5 4 Parameter checking Press it will enter the parameter checking Press or...

Страница 13: ...failure P1 Water temperature sensor open circuit or short circuit Replace the new water temperature sensor Ambient temperature sensor failure P2 Ambient temperature sensor open circuit or short circu...

Страница 14: ...Startup heat pump after a few minutes Short running LED displays actual water temperature no error code displays 1 Fan NO running 2 Air ventilation is not enough 3 Refrigerant is not enough 1 Check th...

Страница 15: ...ransition tube 16 Base 5 Gas collecting pipe 17 Titanium heat exchanger 6 Capillary 18 Coupling tube 7 Electric box 19 Water in temp sensor 8 Cilp 20 Gas collecting pipe 9 Compressor capacitance 21 Ga...

Страница 16: ...5 Electric box 18 Titanium heat exchanger 6 Fan capacitor 19 Water in temp sensor 7 Capillary 20 Gas collecting pipe 8 Controller 21 Low pressure switch Low pressure switch 9 Copper pipe 22 Compressor...

Страница 17: ...ools and filtration system regularly to avoid the damage of the unit as a result of the dirty of clogged filter 3 You should discharge the water from heat pump if it will stop running for a long time...