INSTALLATION, 

OPERATION &  

MAINTENANCE 

MANUAL

IMPORTANT

Please read this manual completely  

before attempting to install or operate this equipment.

Содержание AGF24Z

Страница 1: ...Glass Froster INSTALLATION OPERATION MAINTENANCE MANUAL IMPORTANT Please read this manual completely before attempting to install or operate this equipment...

Страница 2: ...e not followed If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use...

Страница 3: ...teur doivent viter les dommages du tuyau r frig rant ou le rique de la fuite Caution Risk of Fire or Explosion due to Flammable Refrigerant Used Follow Handling Instructions Carefully in Compliance wi...

Страница 4: ...ING AND INSPECTING THE EQUIPMENT Even though most equipment is shipped crated care should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspe...

Страница 5: ...llation Manual 5 SPECIFICATION MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft HP SHELF CAPACITY Sq ft BTU CHARGE OZ NEMA PLUG AGF24Z 115 60 1 2 0 2 67 1 5 4 3 866 3 53 5 15P AGF36Z 115 60 1 2 0 4 50 1 5 6...

Страница 6: ...so full that air cannot circulate The refrigerated air is discharged at the top rear of the unit It is important to allow for proper air flow from the top rear to the bottom of the unit Obstructions...

Страница 7: ...ost The controller now displays the defrost symbol When the coil temperature reaches the terminal temperature or after 20 minutes of defrost the unit will turn on SOLID STATE THERMOSTAT DESCRIPTIONS 1...

Страница 8: ...NUAL DEFFROST Push the key for more than 2 seconds and a manual defrost will start 2 4 HOW TO LOCK THE KEYBOARD 1 Hold the and keys for more than 3s 2 The POF message will be displayed and the keyboar...

Страница 9: ...in a clean condenser coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the cond...

Страница 10: ...brittle and prevent proper seals Do not use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be replaced and don t requi...

Страница 11: ...ation Manual 11 WIRING DIAGRAM MODEL AGF24Z AGF36Z PLUG THERMOSTAT DISPLAY ROOM EVAP SENSOR CONDENSEN FAN THERMAL CUT OFF DEFROST HEATER OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR...

Страница 12: ...Service and Installation Manual 12 WIRING DIAGRAM MODEL AGF24Z AGF36Z...

Страница 13: ...r ACP counter top models and or any model being used in mobile outdoor use application Conditions All service under this warranty for either labor or parts must be performed by a preferred service pro...

Страница 14: ...Broich Enterprises Inc Arctic Air 7550 Market Place Drive Eden Prairie MN 55344 Phone 952 941 2270 Fax 952 941 3066 Website www arcticairco com...