INSTALLATION, 

OPERATION &  

MAINTENANCE 

MANUAL

Pizza Prep Tables
Sandwich/Salad Units
Under-counter Refrigerators 

and Freezers
Worktop Refrigerators and 

Freezers

IMPORTANT

Please read this manual completely  

before attempting to install or operate this equipment.

Содержание AF49

Страница 1: ...TENANCE MANUAL Pizza Prep Tables Sandwich Salad Units Under counter Refrigerators and Freezers Worktop Refrigerators and Freezers IMPORTANT Please read this manual completely before attempting to install or operate this equipment ...

Страница 2: ...re not followed If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the app...

Страница 3: ...ur doivent éviter les dommages du tuyau réfrigérant ou le rique de la fuite Caution Risk of Fire or Explosion due to Flammable Refrigerant Used Follow Handling Instructions Carefully in Compliance with U S Government Regulations Component parts shall be replaced with like components and that servicing shall be done by factory authorized service personnel so as to minimize the risk of possible igni...

Страница 4: ...ge the set point 11 Manual Defrost 11 Keyboard Lock 11 Keyboard Unlock 11 Alarm Codes 11 Display and Reset Alarm 11 MAINTENANCE 12 Refrigerators and Freezers 12 Cleaning the Condenser Coil 12 Stainless Steel Care and Cleaning 12 Gasket Maintenance 13 Doors Hinges 13 Drain Maintenance 13 Door Replacement and Adjustment 13 Open the Bottom Shroud 13 WIRING DIAGRAMS 14 Models Models Models APP 48R APP...

Страница 5: ...RGE Oz SHIP WEIGHT Lbs NEMA PLUG AST 28R 115 60 1 5 7 8 14 3 8 3200 9 5 2 5 15P AST 48R 115 60 1 7 12 12 26 1 2 5400 9 5 313 5 15P UNDERCOUNTER WORKTOP REFRIGERATORS MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft SHELF CAPACITY Sq ft HP BTU CHARGE Oz SHIP WEIGHT Lbs NEMA PLUG AUC 27RZ 115 60 1 1 5 6 5 14 3 8 2800 2 47 243 5 15P AUC 48RZ 115 60 1 3 12 26 3 8 3000 2 65 300 5 15P UNDERCOUNTER FREEZERS MOD...

Страница 6: ...l REGISTRATION The installation date and appliance model must be documented by the end purchaser Also refer to the Warranty section for additional details on registering the appliance Dealer Information Installer Information Installation Date ...

Страница 7: ...state and federal regulations WARNING Make sure all facility electrical connections are in compliance with all local and federal electrical code regulations Inspection and Maintenance WARNING Appliance maintenance must be carried out by only by suitably trained personnel WARNING Before any maintenance work is performed the appliance must be disconnected from the electrical supply Apply a lockout t...

Страница 8: ...ng unloading and on site transporting 1 Visually inspect the exterior of the package skid and or container Report any damage to the carrier immediately 2 If any packaging damage is noted open and inspect the contents with the carrier 3 If concealed damage is discovered after unpacking the equipment notify the carrier Notification must be made both in writing and verbally 4 Check the compressor com...

Страница 9: ...de or back for any reason allow a minimum of 24 hours in the upright position before start up to allow compressor oil to flow back to the sump Failure to meet this requirement can cause compressor failure unit damage and will void the unit warranties Electrical connection Refer to the amperage data provided in the SPECIFI CATIONS the serial tag the local electrical code and or the National Electri...

Страница 10: ... 1a 8a 3a 2a 2 8 7 4 5 6 3 Callout No Control Indicator Function 1 Fan Indicates the fans are running 2 Defrost Press to start the manual defrost cycle 3 Compressor Indicates the compressor is running 4 Up Arrow To display the last temperature alarm In programming mode it browses the parameter codes or increases the displayed value 5 Down Arrow To display the last temperature alarm In programming ...

Страница 11: ...ard is locked With the keyboard locked only the set point or the max min temperature is displayed 3 If any key is pressed for more than three seconds the POF message is displayed Keyboard Unlock Press the Up Arrow and Down Arrow buttons and hold for a minimum of three seconds The Pon message is displayed when the keyboard is unlocked Alarm Codes CODE CAUSE OUTPUTS P1 Room probe failure Compressor ...

Страница 12: ...can damage the electrical components located near or on the condenser coil Stainless Steel Care and Cleaning Stainless steel contains 70 80 iron which will rust It also contains 12 30 chromium which forms an invis ible passive film over the steel s surface that acts as a corrosion shield As long as the protective layer remains intact the metal remains stainless If the film is broken or contaminate...

Страница 13: ...connected from the evaporator housing to the condensate evapora tor drain pan If water has collected underneath the unit check the condensate evaporator drain tube to be sure it is still located inside the drain pan Leveling the unit is im portant because the units are designed to drain properly when level If the floor is not level drain problems may oc cur Be sure all drain lines are free of obst...

Страница 14: ...ONDENSER FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR PTC STARTER CIRCUITALION FAN MOTOR t L N ROOM EVAP SENSOR DOOR FRAME HEATER M M L N THERMOSTAT DISPLAY PLUG CIRCUITALION FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR ROOM EVAP SENSOR DOOR FRAME HEATER MIDDLE FRAME HEATER CONDENSER FAN MOTOR STARTING CAPACITOR CURRENT RELAY ...

Страница 15: ...MOTOR ROOM EVAP SENSOR THERMOSTAT DISPLAY DOOR FRAME HEATER CONDENSER FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR t PTC STARTER L N PLUG CIRCUITALION FAN MOTOR L N ROOM EVAP SENSOR THERMOSTAT DISPLAY DOOR FRAME HEATER MIDDLE FRAME HEATER t CONDENSER FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR PTC STARTER ...

Страница 16: ...THERMOSTAT DISPLAY ROOM EVAP SENSOR CONDENSEN FAN OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR FAN POWER EVAP FAN DOOR SWITCH L N PLUG THERMOSTAT DISPLAY ROOM EVAP SENSOR CONDENSEN FAN OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR FAN POWER EVAP FAN DOOR SWITCH L N ...

Страница 17: ...THERMAL CUT OFF DEFROST HEATER OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR FAN POWER EVAP FAN DOOR SWITCH N L PLUG THERMOSTAT DISPLAY ROOM EVAP SENSOR CONDENSEN FAN THERMAL CUT OFF DEFROST HEATER OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR MIDDLE FRAME HEATER FAN POWER EVAP FAN DOOR SWITCH N L ...

Страница 18: ...18 Installation Operation Maintenance Manual Models APP 48R ...

Страница 19: ...19 UNDER COUNTER REFRIGERATORS AND FREEZERS Models APP 71R ...

Страница 20: ...20 Installation Operation Maintenance Manual Models AST 28R ...

Страница 21: ...21 UNDER COUNTER REFRIGERATORS AND FREEZERS Models AST 48R ...

Страница 22: ...22 Installation Operation Maintenance Manual Models AUC 27RZ ...

Страница 23: ...23 UNDER COUNTER REFRIGERATORS AND FREEZERS Models AUC 48RZ ...

Страница 24: ...24 Installation Operation Maintenance Manual Models AUC 27FZ ...

Страница 25: ...25 UNDER COUNTER REFRIGERATORS AND FREEZERS Models AUC 48FZ ...

Страница 26: ...l being used in mobile outdoor use application Conditions All service under this warranty for either labor or parts must be performed by a preferred service provider arranged by the Arctic Air Warranty Center at 1 855 431 5558 Proof of purchase will be required to validate warranty coverage dates Service coverage is limited to units located in the United States and Canada only Limitations Exclusiv...

Страница 27: ...Broich Enterprises Inc Arctic Air Eden Prairie MN 55344 Phone 952 941 2270 Fax 952 941 3066 Website www arcticairco com ...