background image

Follow the instructions contained in this document 

to ensure safe handling of the battery used with 

this tool.

November 29, 2017

HK1211

Makers of Huck

®

, Marson

®

, Recoil

®

Brand Fasteners, Tools & Accessories

Instruction Manual

 

B1100 

series

Battery-Powered Tool

EC Declaration of 

Conformity

2

Safety Instructions

3-4, 8

 

Description

5

Principle of Operation

5

Specifications and Battery 

and Charger Safety

5-6

Maintenance

6

Preparation for Use

7

Operating Instructions

7

Components Drawing

8

Attaching a Nose Assembly

9

Kits and  Accessories

10

Troubleshooting

10

Содержание B1100 Series

Страница 1: ...eners Tools Accessories Instruction Manual B1100 series Battery Powered Tool EC Declaration of Conformity 2 Safety Instructions 3 4 8 Description 5 Principle of Operation 5 Specifications and Battery and Charger Safety 5 6 Maintenance 6 Preparation for Use 7 Operating Instructions 7 Components Drawing 8 Attaching a Nose Assembly 9 Kits and Accessories 10 Troubleshooting 10 ...

Страница 2: ...2 B1100 Battery Powered Tools HK1211 ...

Страница 3: ...p hands clear from front of tool II PROJECTILE HAZARDS 1 Disconnect the assembly power tool from energy source when changing inserted tools or accessories 2 Be aware that failure of the workpiece accessories or the inserted tool itself can generate high velocity projectiles 3 Always wear impact resistant eye protection during tool operation The grade of protection required should be assessed for e...

Страница 4: ...ory protection in accordance with employer s instructions and as required by occupational health and safety regulations VIII NOISE HAZARDS 1 Exposure to high noise levels can cause permanent disabling hearing loss and other problems such as tinnitus therefore risk assessment and the implementation of proper controls is essential 2 Appropriate controls to reduce the risk may include actions such as...

Страница 5: ...um BobTail fasteners and is compatible with standard L version noses Specially designed for low volume production environments these installation tools are portable with no hoses or cords Batteries are easily replaced and or recharged when they have been depleted of life 11 22 28 2 99 7 0 1 06 2 3 2 68 6 8 11 42 29 1 5 3 8 4 45 11 3 inches cm 3 08 7 8 2 75 6 99 The nose assembly is placed over the...

Страница 6: ...hen the tool is disassembled for any reason Battery and Battery Charger Safety BATTERY CHARGER SAFETY RULES The charger must be used exclusively to charge the batteries that came with your tool Use only the battery intended for HUCK B4600 battery tool Charge only when environment temperature is between 23 131 F 5 C to 55 C Optimum operating temperature range 50 122 F 10 50 C Store batteries in a d...

Страница 7: ...press the switch The tool assumes the front end position and is again ready for use This tool is fitted with an acoustic warning device which provides information about the remaining battery time Beeps sound to tell the user when to change the battery This ensures that the tool will not switch off during operation 3 beeps and flashing LED lights for 10 seconds The battery needs to be changed soon ...

Страница 8: ... Motor 508742 508741 Motor Control 508743 Pintail Container 508745 508749 Plate Screw 508738 Wiring Harness 508748 508736 Screws Drive Unit 508751 Drive Unit 130944 Nose Adapter Assy 508737 Screws 508736 Screw 111795 Retaining Nut Anvil Adapter 130944 4382 2 Ball Screw Adapter O ring ...

Страница 9: ... of nose assembly onto puller then while holding piston rod flats with a wrench screw puller and cap onto tool piston until wrench tight 3 Slide anvil assembly over puller and into tool nose adapter 4 Thread retaining nut onto nose adapter and wrench tight 99 7932L Nose Assembly Anvil Assembly Puller Cap Puller ...

Страница 10: ...3 Tool overloaded LED flashes slowly 1Hz a Check that fastener installation requirements are within the tool s work capacity see page 9 4 Tool will not return collet to forward position a Check that there is no blockage in the anvil housing see page 9 Always check the simplest possible cause of a malfunction first For example a loose or disconnected trigger line Then proceed logically eliminating ...

Страница 11: ...part of a complete overhaul Determination is made on a case by case basis upon return of parts to Huck International Inc for evaluation Tooling Part s and Other Items not manufactured by Huck HUCK makes no warranty with respect to the tooling part s or other items manufactured by third parties HUCK expressly disclaims any warranty expressed or implied as to the condition design operation merchanta...

Страница 12: ...t C Stafford Park 7 Telford Shropshire England TF3 3BQ 01952 290011 FAX 0952 290459 Us Operations BP4 Clos D Asseville 95450 Us par Vigny France 33 1 30 27 9500 FAX 33 1 34 66 0600 AUSTRALIA Melbourne Operations 11508 Centre Road Clayton Victoria Australia 3168 03 764 5500 Toll Free 008 335 030 FAX 03 764 5510 Huck is Forever For the Long Haul The Future of Fastening Technology The Future of Assem...