Archgard Optima 34 34-DVI34N Скачать руководство пользователя страница 39

Optima 34

 

39

 

FREQUENTLY ASKED QUESTIONS 

Listed below are some frequently asked questions regarding Archgard Gas Fireplaces. If you have ques-
tions that are not listed below, or are not answered in this manual, please contact your Authorized 
Archgard Dealer. 

 

Q.

 My glass has a condensation “fog” when the appliance is first lit.  

A.

 Condensation is normal and will disappear in a few minutes after the glass is heated. 

 

Q. 

I have a white “film” on my glass. What is the best way to clean the inside of the glass.  

A. 

Frequent cleaning of your glass is recommended. Archgard recommends using a good quality “gas 

fireplace” glass cleaner that is available at all authorized dealers. Do not use abrasive materials, and do 
not clean the glass or the appliance when the unit is hot.  

 

Q. 

How do I care for my gold plated trims.  

A. 

Archgard recommends a cleaning with a damp cloth. DO NOT use chemical cleaners as they may 

harm the finish, and void your warranty.  NOTE: If the top louvers, or top overlay starts to discolor, check 
the door gasket seal and replace if necessary.  

 

Q. 

My fan/blower makes a “whirring” or “humming” noise.  

A. 

Your Archgard gas appliance uses a powerful fan to push heated air into your room. It is not unusual 

to hear a “humming” noise when your fan is running. Note: the sound will change depending on the set-
ting that your fan speed control is set at. 

 

Q. 

I hear a “click” when my fan system activates.  

A. 

When your appliance reaches temperature, it will activate the THERMODISC “fan switch”. The switch 

closes the electrical circuit that allows the fan to turn on. This is a normal sound.  

 

Q. 

I hear a “ticking”, “cracking” or “pinging” sound when my fireplace is running, and after it is turned off. 

A. 

The different gauges of steel used to manufacture your fireplace will expand and contract at different 

rates when your fireplace is on, and will continued as your fireplace completes its heating function. You 
will likely hear these same sounds more on start up and shut down. This is normal for steel fireplaces. 

 

Q. 

When my appliance is OFF and my pilot light is lit, I hear a “whisper” sound. 

A. 

The lit pilot can make a small noise. Sometimes in extreme wind conditions you may be able to hear 

air entering into the firebox chamber.  

 

Q. 

I hear a “click" when my main burner turns ON or OFF. 

A. 

Your Gas Control Valve will make a clicking sound when it opens to allow gas to flow to the main 

burner. This is a normal part of the operating system.   

 

Q. 

Can I burn wood and other materials in my gas fireplace.  

A. 

No! Burning anything other than natural or LP gas in a gas fireplace or stove will create a potential fire 

hazard and present a danger to your home and its occupants. Only burn the gas fuel for which the unit 
was originally designed. 

 

Q. 

Can I shut my pilot off in the summer? 

A. 

You will save energy by turning off the pilot light if you are not using your appliance for the hot sum-

mer months.  Remember to relight it before you want to use the appliance for the first time in the fall. Re-
fer to your owners manual for lighting instructions. 

 

Q. 

Can I position my gas logs in a different fashion or use a different log set? 

A. 

No. Your gas fireplace is an engineered system that includes the firebox, burner, logs, venting and 

options which are tested and listed by CSA. Changing any specifications or placement of the logs could 
void your manufacturer's warranty, and possible even your homeowner's warranty. 

Содержание Optima 34 34-DVI34N

Страница 1: ...ther appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor...

Страница 2: ...spector of the side wall horizontally vented gas fueled equipment shall not approve the instal lation unless upon inspection the inspector observes carbon monoxide detectors and signage installed in a...

Страница 3: ...a heat activated circulation fan with a fully adjustable speed control Adjustable Flame The flame aesthetics and heat output can be adjusted to suit the owner s liking and heating needs Solid Constru...

Страница 4: ...n Check and Initial Operation 23 First Fire and Lighting Instructions CAUTION 24 Lighting Instructions on Rating Plate 25 Glass Door Removal If Your Glass Should Break 26 Troubleshooting Guide 27 28 M...

Страница 5: ...is imperative that the control compartments burners and circulating air passageways of the appliance are kept clean Do not use this appliance if any part has been under water Immediately call a qualif...

Страница 6: ...d that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists SPECIFICATIONS Natural Gas NG Prop...

Страница 7: ...tal parts of the fireplace in which the gas fireplace insert is to be installed is prohibited If the factory built fireplace has no gas access hole s provided an access hole of 1 1 2 37 5 mm or less m...

Страница 8: ...tible mantle allowed in shaded area Mantle extension maybe increased 1 25 mm for each additional 1 25 mm increase in clearance height Example If using a 5 127 mm reduce minimum height to 36 914 mm If...

Страница 9: ...s supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do...

Страница 10: ...ostat installed and wired to a three prong grounding plug for your protection against shock hazard and should be plugged in directly into a properly grounded three prong receptacle Do not cut or remov...

Страница 11: ...00 mm X 178 mm Masonry chimneys may take various contours which the flexible liner will accommodate however keep the flexible liner as straight as possible avoiding unnecessary bending but at all time...

Страница 12: ...ovided with the unit on Natural Gas appliances only For vent heights between 14 4 25 Meters and 20 6 1 Meters use restrictor 1 for vent height installations over 20 6 1 Meters use restrictor 2 Seal an...

Страница 13: ...nly Trim kit s supplied by the manufacturer should be used in the installa tion of this appliance 1 Using the trim clips provided join the left side trim which has a notch cut for rocker switch to the...

Страница 14: ...ny wall switch or wall thermostat and will not extend warranty to them OPTIONAL WALL SWITCH OR THERMOSTAT Thermostat wall switch wire table Recommended Maximum Lead Length for two wires Wire Size Max...

Страница 15: ...d if removed for servicing as they can be damaged or broken if not handled properly After opening the brick or reflective glass panels set package inspect to ensure that no damage has occurred inside...

Страница 16: ...Optima 34 16 Right Brick Panel Placement as Shown...

Страница 17: ...17 Left Brick Panel Placement as Shown NOTE Installing the panels in any other position other than shown will result in flame im pingement causing sooting of the logs brick liner and ceramic glass vie...

Страница 18: ...be made before installing the embers and logs on the pan burner NOTE Improper placement of logs and embers may cause sooting on the internal parts and glass and will not be covered under warranty Do...

Страница 19: ...nued LOG 7201 LOG 7207 Step 2 Locate Log with 7201 stamped on the bottom and place it as shown Step 1 Locate Log with 7207 stamped on the bottom and place it as shown IMPORTANT Back of log 7201 must r...

Страница 20: ...Optima 34 20 LOG PLACEMENT Continued LOG 7203 Step 3 Locate Log with 7203 stamped on the bottom and place it as shown Step 4 Locate Log with 7202 stamped on the bottom and place it as shown LOG 7202...

Страница 21: ...tima 34 21 LOG PLACEMENT Continued Step 5 Locate Log with 7204 stamped on the bottom and place it on the front pins as LOG 7204 Step 6 Locate Log with 6 stamped on the bottom and place it as shown LOG...

Страница 22: ...Optima 34 22 Step 7 Locate Log with 5 stamped on the bottom and place it as shown LOG 5 Black embers Step 8 Place black embers around logs as shown do not cover the holes in the burner...

Страница 23: ...1 Perform leak tests of supply line gas control valve supply line from gas control valve and pilot assembly 2 Clocking the appliance to ensure the correct firing rate see page 9 of this manual 3 If re...

Страница 24: ...ervice technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water WARNING If you do not follow these instructions exactly a fire o...

Страница 25: ...of explosion may result causing property damage personal injury or loss of life 1 STOP Read the safety information above on this label 2 Set the remote switch to OFF Set the thermostat to the lowest s...

Страница 26: ...y at a safe location where it cannot be scratched or damaged Replacing the Glass Door The reverse procedure of Removing the Glass Door IF YOUR GLASS BREAKS WARNING Do not operate appliance with the gl...

Страница 27: ...ive Pilot will not remain on after being lit 1 Press the control knob all the way in at the pilot indicator 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the p...

Страница 28: ...eck wire connections Expansion from heat affects a loose connec tion Sooty deposits on the glass door 1 If the flame is yellow and lazy check for lint etc around primary air shutter Increase primary a...

Страница 29: ...uum cleaner to clean off any dust or lint After cleaning the logs and embers must be replaced as per the instructions in this manual Once a year have a qualified service technician Completely inspect...

Страница 30: ...old All replacement parts must be authorized by Archgard for suitability Note the Shutter is set at the factory and normally only requires resetting at higher altitudes Caution Wear gloves when adjust...

Страница 31: ...manual for reassembly 3 Remove the logs See LOG PLACEMENT for instructions 4 Unscrew the two mounting screws that are located at the back rear of the pan burner 5 Carefully remove the pan burner by s...

Страница 32: ...INLET AND OUTLET GAS PRESSURE CHECKING AND ADJUSTING PILOT Fig 1 CONVERTIBLE PILOT ORIFICE The pilot assembly is convertible to the type of gas being used simply unscrew the body by using a 7 16 11 mm...

Страница 33: ...ions within this manual 2 Remove the log set Follow LOG PLACEMENT instructions within this manual 3 Loosen the adjustment wing nut and slide the air shutter to the left Follow ADJUSTING PRIMARY AIR in...

Страница 34: ...Orifice Drill to 34 DMS 2 76 mm for Natural Gas Drill to 51 for LP Propane Gas 1 EA E 620 0004 Aluminum Pilot Box 1 EA F 314 0127 Gasket Ceramic Paper 1 EA G 314 0127 Gasket Ceramic Paper 1 EA H 308 0...

Страница 35: ...Qty Unit 310 634720 1 Log 7201 1 EA 310 634720 2 Log 7202 1 EA 310 634720 3 Log 7203 1 EA 310 634720 4 Log 7204 1 EA 310 634720 5 Log 7205 there is only 5 on log 1 EA 310 634720 6 Log 7206 there is on...

Страница 36: ...1 Air Shutter Gasket 2 IN 800 0031 Wiring Harness assembly for On Off Rocker Switch 1 EA 305 0019 On Off Rocker Switch 1 EA Fan Components 305 0012 Power Cord 8 2 43 M 1 EA 305 0013 Fan Speed Control...

Страница 37: ...onal Surround Trims 34 TKSB Black Trim for SKBAB SKCAB surround 1 SET 34 TKLB Black Trim for SKLB surround 1 SET 34 TKSG Gold Trim for SKBAB SKCAB surround 1 SET 34 TKLG Gold Trim for SKLB surround 1...

Страница 38: ...Archgard Dealer WHAT TO DO IN THE EVENT OF A PROBLEM Thoroughly read your manual If you cannot solve the problem contact your Archgard Dealer or representative When calling for help please have the fo...

Страница 39: ...ing cracking or pinging sound when my fireplace is running and after it is turned off A The different gauges of steel used to manufacture your fireplace will expand and contract at different rates whe...

Страница 40: ...Optima 34 40 NOTES...

Страница 41: ...ame Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card mm dd yyyy POSTAGE FOLD DOWN AT LINE FOLD DOWN AT LI...

Страница 42: ......

Страница 43: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Отзывы: