Optima 34
12
Instructions for use with Archgard vertical termination cap. Part # 999-INS-TK
Install the termination cap being sure to provided sufficient space (around and on top) so as not
to impede the flow of air, both into and out of the cap. This cap is only to be used for non com-
bustible installations. Do not recess into the top of the chimney.
1.
Mark each end of one liner with
“Air Intake”.
2. Mark each end of the second liner with
“Exhaust”.
3. Pull the liner through the chimney.
4. Install the flashing.
Do Not bend or cut the flashing in any way.
5. Seal and attach the liner marked
“Air Intake”
to the vent terminal pipe marked
“Air Intake”
with the collar
clamp provided.
6. Seal and attach the liner marked
“Exhaust”
to the vent terminal pipe marked
“Exhaust”
with the collar clamp
provided.
7. Seal and attach the end of the flex marked
“Air Intake”
to the collar marked
“Air Intake”
on the appliance
with the collar clamp provided with the unit.
8.
Install exhaust vent restrictors provided with the unit on Natural Gas appliances only. For vent heights
between 14’ (4.25 Meters) and 20’ (6.1 Meters) use restrictor #1, for vent height installations over 20’ (6.1
Meters) use restrictor #2.
Seal and attach the end of the flex marked
“Exhaust”
to the collar marked
“Exhaust”
on the appliance with the collar clamp provided with the unit..
10. Caulk all joints as usual.
NOTE: The vertical termination cap must be sealed to the liner with suitable high temperature sealant and with the
hose clamps fasteners provided. The liners must form a complete connection from the ap-
VENTING INSTRUCTIONS 999-INS-TK
The minimum flue (chimney) size required to run the two 3” (76 mm) is 4” x7” (100 mm X 178 mm)
Front view of
DV Insert
Air Intake
Collar
Exhaust
Exhaust
Collar
3” (76 mm)
Flex Liner
Fresh Air
Intake
Min. vent height 8’ (2.44 M)
Max. vent height 35’ (10.6 M)
Vertical Termination cap
Part # 999-INS-TK
Place Vent Restrictor
in the position shown
(on the exhaust collar
before attaching the
Flex Liner
)
ONLY
when operating with
NATURAL GAS
with a
VENT OF 14’ to
20’ (6.1 m) restrictor
#1 AND 20’ (6.1 m)
ABOVE
restrictor #2
Note Vent restrictor # 1 is the
item with the notch (restrictor #
2 shown in picture