Archgard OPTIMA 30 - 1 Скачать руководство пользователя страница 27

 
 
 
This Limited Warranty is made by ARCHGARD INDUSTRIES LTD, hereinafter referred to as “Archgard”. Archgard warrants to 
the original purchaser of an Archgard gas burning fireplace (s) that the product will be free of defects in materials and workman-
ship under normal use and service, for a “lifetime”. 

 

INCLUSIONS: “LIFETIME LIMITED WARRANTY“ 

• 

All heat exchangers, combustion chamber, burner tubes and pans.   

• 

Ceramic Fiber Logs and Ceramic Brick Panels against splitting or cracking. 

• 

Ceramic Glass against thermal breakage. 

• 

All 24 K gold trims and accessories against tarnishing. 

• 

All trim accessories against tarnishing and paint defects. 

• 

Note

: Discoloration and some minor movement of certain parts are normal and are not a defect and therefore, not  

 

       covered under warranty.   

The above will be covered “parts & labor” to the original purchaser for FIVE years and “parts” only thereafter from original date 
of purchase. 

 

INCLUSIONS: “FIVE YEAR LIMITED WARRANTY” 

• 

Five year limited warranty on the “FiberFlame Technology Burner System.”  Warranty will cover any defective burner and 
ceramic ember bed if defect is deemed as original by the manufacturer. 

The above will be covered “parts & labor” to the original purchaser for TWO years and “parts” only thereafter from original date 
of purchase. 

 

INCLUSIONS: “ONE YEAR LIMITED WARRANTY”  

• 

Blowers, fans and fan motors, wiring, rheostats and thermodiscs. 

• 

Rocker switches, spill switches and wiring to them.  

• 

Gas control valves, pilot assemblies including thermopiles, thermocouples, electrodes, and igniters. 

The above will be covered “parts & labor”  to the original purchaser for ONE year from date of purchase.  

 

EXCLUSIONS: 

• 

Archgard does not offer wall mounted thermostats, programmable thermostats (wiring for hook-up of said product), 
handheld remote controls, fireplace mantel (s), trims or tiles.  

• 

Tempered Glass is warranty for ONE year to the original purchaser from date of purchase. 

• 

Travel time or mileage to original purchasers residence. Archgard suggests that you pre-arrange travel expenses with 
your Authorized Archgard Dealer. 

 

 

WHAT TO DO IN THE EVENT OF A PROBLEM: 

• 

Thoroughly read your manual. 

• 

If you cannot solve the problem, contact your Archgard Dealer or representative.  

• 

When calling for help please have the following information:  

            

Model of your Fireplace.             Serial Number.                  Place or Purchase.                            

            Date of Purchase.                  Problem Description. 

• 

NOTE: Warranty may be void if work is carried out by an unqualified person (s). Only original Archgard parts may be 
used. Please consult your Archgard dealer or representative if in doubt about a replacement part (s). 

 

OBTAINING WARRANTY SERVICE: 
To obtain warranty service, the original purchaser shall return the defective part (s) to the original authorized Archgard selling 
dealer transportation prepaid, along with the serial number of the appliance and proof of purchase. Any defective part, in our  
judgment, will be repaired or replaced at Archgard’s discretion. The dealer must obtain approval from Archgard before any  
repairs are made.  

 

WARRANTY LIMITATION: 
THIS LIMITED WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED AS TO QUALITY, 
MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE. 

 

The appliance is only warranted for the use as intended by the installation and operating instruction and local building codes. 
The warranty will not cover damage due to accident, misuse, abuse, alteration, improper installation or “acts of god”.  
This limited warranty is void unless the appliance is installed by a qualified installer, in accordance with the instructions  
furnished with the appliance. Some Provinces or States do not allow limitations on how long an implied warranty lasts, so the 
above limitation may not apply to the original purchaser. Any damage resulting from defects in this product, is limited to the  
replacement of the defective part (s) and does not include incidental and consequential exposures sustained in connection with 
the product. This includes facing (s),   mantel (s), cabinet (s), tile (s) or any other finishes resulting from removal of any gas  
appliance. This warranty is limited to residential use only and gives the consumer specific rights. These rights may vary from 
State to State or Province to Province.  

ARCHGARD LIMITED WARRANTY 

f i r e - p a r t s . c o m

Содержание OPTIMA 30 - 1

Страница 1: ...loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not tou...

Страница 2: ...fire parts com...

Страница 3: ...hould be carefully supervised when they are in the same room as the appliance Clothing or other flammable material should not be placed on or near the appliance Do not operate with cracked or broken g...

Страница 4: ...eed control Adjustable Flame The flame aesthetics and heat output can be adjusted to suit the owner s liking and heating needs Solid Construction The Optima 30 is constructed mainly of 16 and 18 gauge...

Страница 5: ...e or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 HIGH ALTITUDE INSTALLATION When installing this appliance beyond 4500...

Страница 6: ...OPTIMA 30 1 6 APPLIANCE DESCRIPTION TOP VIEW FRONT VIEW LOG SET BRICK PANELS BOTTOM GRILL GLASS DOOR TOP GRILL SLIDING FLUE CONNECTOR ON OFF SWITCH SPILL SAFETY SWITCH fire parts com...

Страница 7: ...3 mm G 18 3 4 476 mm H 20 3 8 518 mm I 21 7 8 556 mm J 1 3 4 45 mm K 5 5 8 143 mm E 44 1 2 1130mm F 30 762 mm With standard aluminum surround Flue Collar 4 102 mm diameter DIMENSIONS AND CLEARANCES MI...

Страница 8: ...152mm Minimum Height From Bottom of Applinace with a 6 152mm Mantel as shown in this picture 37 940mm WARNING Failure to position the parts in accordance with these diagrams or failure to use only pa...

Страница 9: ...est pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas valve Such damage is not covered by the manufacturer s warranty Natural Gas Pressure Settings The...

Страница 10: ...e black supply conductor to the free black conductor from the speed controller with a marrette type wire connector Connect the neutral white supply conductor to the free white conductor from the conve...

Страница 11: ...the chimney have it cleaned of any soot or creosote The appliance is equipped with a vent safety shutoff system and a safety control system designed to protect against improper venting of combustion...

Страница 12: ...ET SLIDING FLUE ADAPTER INSTALLATION INSTRUCTIONS Cont SPILL SAFETY SWITCH SLIDING FLUE ADAPTER FLUE PULL AND FASTENING BAR SCREW HERE AFTER INSTALLATION AND CUT OFF EXCESS BAR WARNING Maximum clear a...

Страница 13: ...LOCATING TABS UPPER LOUVERS REMOVED DOOR LATCHES SHOWN OPEN SWITCH MOUNTING AND WIRING SPILL SWITCH The spill switch is located in a critical location to shut of the appliance in the event the draft i...

Страница 14: ...PLACEMENT OF EMBERS A small bag of ember and coals are provided with the fireplace Carefully place the embers and coals on the ledge between the grate and the front of the burner Do not allow the embe...

Страница 15: ...and the spade connector of the thermal switch on the underside of the firebox Fig 1 6 Remove the sparker wire from the existing piezo sparker 7 Place the rheostat through the corresponding hole in th...

Страница 16: ...ply Check that the logs and branches are properly placed Check that all external parts such as grills door and faceplate are properly attached and fastened Check that there are no finger prints left o...

Страница 17: ...control knob counterclockwise 4to PILOT position depress control knob and light pilot by repeatedly pressing the sparker Venting of air may take place prior to flow of pilot gases Once flame is establ...

Страница 18: ...sition depress control knob and light pilot by repeatedly pressing the sparker Venting of air may take place prior to flow of pilot gases Once flame is established hold knob depressed for approximatel...

Страница 19: ...se wearing a dust mask The logs are very fragile take care not to break them Do not wash logs with any liquid Wile logs are removed also remove the coals or embers and check that all burner openings a...

Страница 20: ...switch Pilot will not remain on after being lit 1 Press the control knob all the way in 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the pilot immediately af...

Страница 21: ...heck to ensure all wires are connected tightly 3 Check for proper drafting of the appliance Correct if drafting is occurring into the room Sooty deposits on the glass door 1 If the flame is yellow and...

Страница 22: ...UTOMATIC MILLIVOLT VALVE CONVECTION BLOWER SPEED CONTROL LINE CONVECTION BLOWER GROUND 110F 43 C N O THERMAL SNAP SWITCH NEUTRAL ELECTRICAL BOX 120 VAC A ELECTRODE B THERMOPILE C PILOT CAP PILOT ASSEM...

Страница 23: ...hutter is set at the factory and normally only requires setting at higher altitudes Open the lower grills Unscrew the 2 screws holding the control panel and remove the panel The primary air adjustment...

Страница 24: ...ET AND OUTLET GAS PRESSURE CHECKING AND ADJUSTING PILOT The pilot flame should have the characteristic as shown in the illustration below The flame should not have yellow tips but should engulf the th...

Страница 25: ...t material Replacement requires Ceramic glass part 307 0023 gasket part 314 0000 and sealer part 319 0005 Install new glass with new gasketing in place The thicker side of the gasket fits against the...

Страница 26: ...8 0000 SIT THERMOCOUPLE NOVA 820 PILOT 1 EA 308 0004 PIEZO WIRE 16 1 EA 308 0005 PIEZO IGNITER C W NUT 1 EA 308 0009 INTERRUPTER BLOCK SIT 1 EA 308 0012 VALVE NOVA SIT 820 HI LOW PROPANE 1 EA 308 0013...

Страница 27: ...thorized Archgard Dealer WHAT TO DO IN THE EVENT OF A PROBLEM Thoroughly read your manual If you cannot solve the problem contact your Archgard Dealer or representative When calling for help please ha...