The appliance is equipped with a vent safety shutoff system and a safety control system
designed to protect against improper venting of combustion products. The appliance will not
function without being connected to a proper venting system.
WARNING: Operation of this heater when not connected to a properly installed and
maintain venting system or tampering with the vent shut-off system can result in carbon
monoxide (CO) poisoning and possible death. This appliance must not be connected to
a chimney flue serving a separate solid fuel burning appliance. The draft hood opening
behind the top louvers must not be obstructed in any way.
The appliance may be vented using 4 in. diameter aluminum or stainless steel flexible gas flue
liner running inside a masonry chimney or the flue of the factory built fireplace. The vent
system must be properly terminated with a suitable vent cap. This cap must be sealed to the
existing with a silicone type high temperature sealer. The liner must form a complete
connection from the flue collar to the vent cap. If maximum heating efficiency is desired, it is
recommended to seal between liner and chimney using non backed fiberglass insulation above
the appliance. Follow the vent component manufacturer’s instruction. Also check with local gas
authorities for proper venting methods and procedures.
The appliance has a detachable flue connection plate for ease of installation. (see page 11). A
45° adapter is available if the vertical orientation of the outlet is difficult to use (Part# FAE-25).
WARNING:
Maximum distance between front of unit and front of flue pipe is 15 1/2”
After the flexible gas liner has been properly installed in the fireplace, attach the collar of the
connector pate to the liner with screws or a clamp. Before placing the appliance into the
fireplace, check the hearth of the fireplace to see if it is level with the front of the fireplace. If it
is not, measure the depth of the hearth. Loosen the three screws of the leveling “L” bracket at
the back of the appliance. Lower it to the measurement obtained and tighten the screws. Make
sure the gas and electrical supply line are properly connected to the appliance. Slide the
appliance into the fireplace, and at the same time slide the flue connection plate back onto the
top of the appliance. Fasten the pull bar with the screw provided in the hood edge so that the
flue adapter cannot slide back out (see page 11). Check the leveling of the appliance. Attach
the faceplate to the appliance before sliding the appliance all the way into the fireplace. The
return flange on the inside of the faceplate sides fits on the inside of the mounting rails on the
appliance. Screw the faceplate to the appliance at the locations shown with the black screws
provided.
VENTING
INSTALLATION INSTRUCTIONS
Cont...
Before starting, check the condition of the chimney have it cleaned of any soot or creosote.
The appliance is equipped with a vent safety shutoff system and a safety control system
designed to protect against improper venting of combustion products. The appliance will
function for short periods and shut down the main burner if it’s not connected to a proper
venting system that is a minimum of 10 Ft (3 m) high , or if there are blockages in the vent.
WARNING: Operation of this heater when not connected to a properly installed and
maintain venting system that is a minimum of 10 Ft (3 m) high or tampering with the
vent shut-off system can result in carbon monoxide (CO) poisoning and possible death.
This appliance must not be connected to a chimney flue serving a separate solid fuel
burning appliance. The draft hood opening behind the top louvers must not be
obstructed in any way.
The appliance may be vented using 4 in. diameter aluminum or stainless steel flexible gas flue
liner running inside a masonry chimney or the flue of the factory built fireplace and must be a
minimum of 10 Ft (3 m) high. The vent system must be properly terminated with an approved
vent cap. This cap must be sealed to the liner with a silicone type high temperature sealer. The
liner must form a complete connection from the flue collar to the vent cap. Follow the vent
component manufacturer’s instruction. Also check with local gas authorities for proper venting
methods and procedures. It is also necessary to seal any gaps around the vent cap and the
existing masonry chimney opening with suitable mortar mix cement.
The appliance has a detachable flue connection plate for ease of installation. (see page 11). A
45° adapter is available if the vertical orientation of the outlet is difficult to use (Part# FAE-25).
WARNING:
Maximum distance between front of unit and front of flue pipe is 15 1/2”
After the flexible gas liner has been properly installed in the fireplace, attach the collar of the connector
pate to the liner with screws or a clamp. Before placing the appliance into the fireplace, check the hearth
of the fireplace to see if it is clean and level with the front of the fireplace. If it is not, measure the depth
of the hearth. Loosen the three screws of the leveling “L” bracket at the back of the appliance. Lower it
to the measurement obtained and tighten the screws. Make sure the gas and electrical supply line are
properly connected to the appliance. Slide the appliance into the fireplace, and at the same time slide
the flue connection plate back onto the top of the appliance. Fasten the pull bar with the screw provided
in the hood edge so that the flue adapter cannot slide back out (see page 11). Check the leveling of the
appliance. Attach the faceplate to the appliance before sliding the appliance all the way into the
fireplace. The return flange on the inside of the faceplate sides fits on the inside of the mounting rails on
the appliance. Screw the faceplate to the appliance at the locations shown with the black screws
VENTING
INSTALLATION INSTRUCTIONS
Cont...
SCREW
LOCATIONS
f i r e - p a r t s . c o m
Содержание OPTIMA 30 - 1
Страница 2: ...fire parts com...
Страница 28: ...OPTIMA 30 1 28 NOTES fire parts com...
Страница 30: ...fire parts com...
Страница 31: ...OPTIMA 30 1 31 NOTES fire parts com...