INSTALLATION INSTRUCTIONS
Cont...
9
INSTALLATION INSTRUCTIONS
Cont...
RESTRICTOR PLACEMENT “FOR ABOVE 7 FOOT VERTICAL RISE VENTED
APPLICATIONS ONLY”
Vertical Venting between Seven Feet (7’) and Ten Feet (10’) requires
Restrictor Number 1 as per the Venting Chart on page 8.
Simpson Duravent
Archgard System
Archgard System
In the Archgard system the restrictors are placed on the exhaust outlet on the appliance.
Simpson Duravent
With Simpson Duravent locate the restrictor in the exhaust section fitting into the formed lip.
Restrictor Placement
WARNING:
These restrictors are only to be installed in the vent system if the vent exceeds 7’
in vertical height. *See below which restrictor is required.
Installing them
under any other circumstances may cause hazardous venting conditions
and may result in personal injury, property damage or death.
NOTE:
Vent restrictors are designed to reduce vertical stack action for above 7 feet (7’),
which will reduce the velocity of incoming combustion air and not adversely affect the standing
pilot or the flame of the appliance.
8
Vertical Venting between Ten Feet (10’) and up to a maximum
Twenty-five Feet (25’) requires Restrictor Number 2 as per the
Venting Chart on page 8.