Archgard NorthFire-DVT36E Скачать руководство пользователя страница 3

INTRODUCTION 

Thank you for purchasing the NorthFire-DVT36E Direct Vent Built-in Gas Fireplace. 
 
The NorthFire-DV36E is one of the most advanced gas fireplaces on the market. It is designed 
using the latest technology and manufactured to the highest quality. 
 
Some of the many features are: 

 

∗ 

Small Size                      The NorthFire-DV36E is compact enough to fit into almost any size 

 room. 

∗ 

Solid Construction         The NorthFire-DV36E is constructed mainly of satin coated and 

galvanized steel for long life and durability. 

 
Please read the manual carefully prior to installation and operation of the appliance. 
Proper installation, operation and maintenance of the appliance will provide you with 
many years of enjoyment. 

 

CAUTION 

 

Due to high temperatures, the appliance should be located out of traffic and away from 
furniture and draperies. 
 
Children and adults should be alerted to the hazards of high surface temperature and 
stay away to avoid burns or clothing ignition. 
 
Young children should be carefully supervised when they are in the same room as the 
appliance. 
 
Clothing or other flammable material should not be placed on or near the appliance. 
 
Any parts removed or opened for servicing of the appliance must be properly replaced 
prior to operating the appliance. 
 
The appliance must be inspected before use and at least annually by a qualified service 
person. More frequent cleaning maybe required due to excessive lint from carpeting, 
bedding material, etc. It is imperative that the control compartments, burners and 
circulating air passageways for the appliance be kept clean. 

f i r e - p a r t s . c o m

Содержание NorthFire-DVT36E

Страница 1: ...phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING THE APPLIANCE WARNING Imp...

Страница 2: ...tions 5 13 Operation Instructions 14 15 Maintenance 16 Trouble Shooting Instructions 17 18 Servicing 19 20 Important Information Form 21 Warranty 22 Parts and Accessories 23 Allowed Termination Locati...

Страница 3: ...njoyment CAUTION Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temp...

Страница 4: ...in Canada Electrical connections and grounding must conform with local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C...

Страница 5: ...CONTROL TOP LOUVERS GLASS DOOR APPLIANCE DIMENSIONS FRONT VIEW 36 1 4 23 1 2 37 3 4 TOP VIEW SIDE VIEW FRONT VIEW 3 1 2 Except for the vent connector locations the rear vented DVR36H and top vented D...

Страница 6: ...ble for venting See APPENDIX A ALLOWABLE TERMINATION LOCATIONS VENT TERMINATION 1 See ALLOWABLE TERMINATION LOCATIONS diagram page 24 to establish a suitable vent termination location 2 In heavy snowf...

Страница 7: ...nt 6 FRAMING DIMENSIONS 36 1 4 16 39 1 2 28 36 1 4 56 36 1 4 31 16 If more rigidity is required A stud may be added to the back of the top nailing flange after the fireplace is installed TERMINATION F...

Страница 8: ...bserve the venting chart given in this manual 5 Use a vent spacer between the inside and outside flex vents at every 3 ft intervals 6 Never slope horizontal running vents downwards 7 Maintain at least...

Страница 9: ...rmed lip Restrictor Placement WARNING These restrictors are only to be installed in the vent system if the vent exceeds 7 in vertical height See below which restrictor is required Installing them unde...

Страница 10: ...NTAL LENGTH from center of flue outlet to base of termination VERTICAL HEIGHT from bottom of appliance to center of termination 7 ft Venting in this area requires a vent restrictor plate 1 5 ft 7 ft 9...

Страница 11: ...he appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or...

Страница 12: ...re two latches under the firebox Undo the latches swing the bottom of the door away from the appliance and then lift the door off the top retaining tabs Carefully place the door in a safe location whe...

Страница 13: ...is provided with the heater Place the fibre coals on the burner tray surrounding the burner DO NOT place fibre coals on the burner itself Tear ember wool into 1 2 to 3 4 diameter ember pieces and plac...

Страница 14: ...ce and into the bottom of the gas fireplace Be sure to connect a grounding wire to the side of gas fireplace Use any screw hole on the side for this purpose Slide the thermal snap switch into the fork...

Страница 15: ...the appliance area for gas Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor IF YOU SMELL GAS follow the instruction on the front cover of this ma...

Страница 16: ...INTERLOCK for proper lighting of pilot Press slightly and turn control knob counterclockwise 4 to PILOT position depress control knob and light pilot by repeatedly pressing the sparker Venting of air...

Страница 17: ...tside the house wearing a dust mask The logs are very fragile take care not to break them After cleaning the logs must be replaced as per the instructions in this manual When replacing glass door ensu...

Страница 18: ...as valve may be defective Pilot will not remain on after being lit 1 Press the control knob all the way in 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the pi...

Страница 19: ...primary air by opening the primary air shutter 2 Check for proper placement of the logs and branches See that section in the instruction manual 3 Check for obstruction of the burner ports by the ember...

Страница 20: ...shutter screw with a Philips screwdriver Rotate air shutter with a flat tip screw driver The primary air opening size can be easily seen with a flashlight Tighten the air shutter screw after adjustmen...

Страница 21: ...ssembly plate to the appliance Gently lift the assembly up and tilt the back up to clear the front of the valve from the opening Replacing the assembly is the reverse of the above instructions Disconn...

Страница 22: ...SS PHONE NUMBER COMPANY NAME ADDRESS PHONE NUMBER APPLIANCE MODEL NUMBER NORTHFIRE DVT36E SERIAL NUMBER GAS TYPE NATURAL GAS LPG VALVE TYPE SIT 820 DATE PURCHASED INSTALLATION INSTALLER NAME DATE INST...

Страница 23: ...doubt OBTAINING WARRANTY SERVICE To obtain warranty service the consumer shall return the defective part to the original selling dealer transportation prepaid along with the serial number of the appl...

Страница 24: ...EMP 16 150x28 843 DV36E 1 EA 308 0005 PIEZO IGNITOR C W NUT JBS 66270 003 1 EA 308 0007 PIEZO IGNITOR FOR MOUNTING ON VALVE SIT 1 EA 308 0022 VALVES DEXEN NG 3 5 WC 3 8X3 8 6003S 1 EA 308 0054 PILOT A...

Страница 25: ...24 fire parts com...

Страница 26: ..._________________________________ Telephone ______ ______ _________ Dealer s Name Address ______________________________________________________ ______________________________________________________...

Отзывы: