GLASS MAINTENANCE (cont’d)

 

 
WARNING:  Never  clean this glass with an  abrasive  cleaner.  Use  only  a  cleaner  recommended  as  a 
wood insert glass cleaner.  Never clean the glass while it is hot; a serious burn can result.  
 

NOTE:

  A  portion  of  the  combustion  air  entering  the  firebox  is  deflected  down  over  the  inside  of  the  door 

glass.  This air flow “washes” the glass, helping to keep smoke from adhering to its surface. 

In a controlled 

combustion firebox, temperatures are not always high enough to keep the glass perfectly clean.  Less air will 
be flowing over the glass and the smoky, relatively cool condition of a low fire will cause the glass to become 
dark.  Operating the stove with the Primary Air Control all the way open for 15-20 minutes should remove 
this built up coating.  If the deposits on the glass are not very heavy, normal glass cleaners should work well.  
Heavier  deposits  may  be  removed  using  wood  insert  glass  cleaner.      Remember  the  drier  the  wood,  the 
cleaner the glass. 

IF YOUR GLASS BREAKS 

 

See your dealer for the exact replacement glass. 

Replace  with  5mm  ce-

ramic glass only.  

The gasket around the glass must be replaced with the 

identical gasket - see your Archgard Dealer. Ensure that the fire is out and 
the insert is cool to the touch. 
1. Protect your work surface with padding or towels. 
2. Remove the door from the insert by lifting it up and off the hinges. 
3. Lay  door  face  down  on  your  work  surface  making  sure  the  handle 

hangs over the edge so the door lays flat on a soft surface. 

4. Remove the 8 bolts holding the glass retainer to the door and remove 

the glass.   

5. Install the new glass and new gasket into the opening and replace the 

glass  retainer  being  careful  not  to 

cross-thread 

or 

over-tighten 

the 

bolts.  

6. Replace the door on the appliance. 

 

PAINT 

 

You may touch up the ARCHGARD 

CHALET  1800  Wood  Fireplace  In-

sert 

with STOVE BRIGHT high temperature paint. The correct paint is available from your dealer. When you 

paint the insert, remove the gold items (i.e., door), and cover the area surrounding the fireplace with newspa-
per. Follow the directions outlined on the spray can. 

DO  NOT 

attempt to paint while the insert is still warm. 

Keep the spray can away from any source of heat or open flame. Ensure that there is adequate ventilation in 
the room from the time you start painting until the paint is dry. 

 

PLATED DOORS 
 

If you have gold or nickel plated doors you will be happy to know that they will not tarnish, however they are 
not scratch resistant. They require a totally abrasive free cleaner. Use only mild soap and warm water  or 
denatured alcohol to clean the gold or nickel when the surface is cool. The use of any household cleaner, 
such as Windex, abrasive cleaners, or any form of acid, may permanently etch or remove some of the gold 
or nickel plating. Before every fire, be absolutely sure to wipe off all fingerprints from the gold or nickel plat-
ing. Acid from debris or even your fingerprints may permanently etch the gold or nickel plating and void the 
warranty.

 

Содержание Chalet 1800I

Страница 1: ...ease keep these instructions for future reference PRIOR TO FIRST FIRE Remove all labels from glass Clean fingerprints from plated surfaces with a glass cleanser and soft cloth to prevent permanent sta...

Страница 2: ...Installation and Removal 26 27 Door And Glass Maintenance 28 29 Paint 29 INSERT INFORMATION FOR INSTALLATIONS Venting Requirements 19 Precautions For Installation 13 Installation Methods 14 18 First F...

Страница 3: ...of your new appliance will be greatly enhanced by becoming familiar with its installation operation and maintenance Prior to installation we ask that you take a few moments to read this manual We wis...

Страница 4: ...earances to combustibles as shown in this manual 11 Build fire on brick firebox floor Do not use grates andirons or other methods to support fuel 12 HOT WHILE IN OPERATION Keep children pets clothing...

Страница 5: ...PR MAY JUN DEC NOV OCT SEPT AUG JUL 2006 2007 2008 UNITED STATES ENVIRONMENTAL PROTECTION AGENCYCERTIFIED TO COMPLY WITH JULY 1999 PARTICULATE EMMISSIONS STANDARDS SERIAL XXXXX HOT WHILE IN OPERATION...

Страница 6: ...ening and 8 to the sides and rear of the unit Consult with your local inspector authority having jurisdiction or check the NFPA 211 or local codes In Canada the floor pad ember protection must be of n...

Страница 7: ...8 mm Optional 24 609 mm 21 75 553 mm 21 75 553 mm 25 25 641 mm 6 125 154 mm 28 711 mm 27 875 708 mm 40 1016 mm 20 508 mm 24 610 mm Adjustable 9 12 229 305 mm 27 875 708 mm 6 ID 152 4 mm Adjustable 9 1...

Страница 8: ...mm E P A EMISSIONS 3 6 grams hour E P A OUTPUT RATING 10 700 35 500 BTU HR 3 134 10 397 watt APPROXIMATE HEATING AREA 800 1 500 FEET2 74 3 139 4 METRE2 DURATION ON LOW FIRE 6 10 HOURS INSERT BODY WEIG...

Страница 9: ...nsert a piece of paper between the door and the stove body You shouldn t be able to pull the paper out Tighten it to the point where the paper is starting to tear when you are pulling it out 6 Insert...

Страница 10: ...them into the adjustable keyhole slots in the top faceplate but don t tighten them down yet Then being careful to start the left leg over the air shutter control on the left side of the unit slide th...

Страница 11: ...s from the fan to the matching male connectors on the snap disc 5 Align the holes in the sides of the fan housing with the holes in the two brackets that were just installed and attach with the black...

Страница 12: ...nd allow full control of the fan Switching from AUTO to MAN or HIGH to LOW may be done anytime CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper a...

Страница 13: ...es in Canada or any other applicable local code requirements and is OK to have an insert installed into it and also ensure that the flue is free of creosote Do not connect the insert to a chimney syst...

Страница 14: ...of the insert This blocker plate is installed and a stainless pipe stainless steel because it is in a concealed space do not use black or galvanized pipe installed through the hole and up to the firs...

Страница 15: ...the insert is ever removed 2 Drop the liner down from the top of the chimney If it is a tight fit or if offsets are present you may have to at tach a cone to the end of the liner with some rope com i...

Страница 16: ...into the top of the insert then you can reach in and get the liner and fit it into the flue collar and mechanically attach it If the room is not there then install the optional flex to rigid adaptor...

Страница 17: ...keting some masonry anchors and some stainless steel liner to go from the top of the flue collar of the insert to the first flue tile in the chimney 3 With a piece of soapstone or chalk mark a line us...

Страница 18: ...g like this makes installation much easier if you have to install through the appliance slip in the cross bar and screw on the two nuts following the manufacturers instructions 13 Push the liner up so...

Страница 19: ...ll burn very slowly and could soot the appliance When shutting down the insert fully open the air con trol This allows the chimney temperatures to remain as high as possible for as long as possible Co...

Страница 20: ...tes a condition known as negative pressure When a negative pressure situation is experienced the combustion gases can be drawn from the chimney and into the house This condition is commonly referred t...

Страница 21: ...ve Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Will not burn Overni...

Страница 22: ...s can produce creosote quickly be cause they can t burn the wood as completely as advanced combustion designs In severe cases of smol dering it may take only a few days for enough creosote to build up...

Страница 23: ...s nec essary during the season as creosote deposits may build up rapidly Moving parts of your insert require no lubrication Have the chimney system cleaned when a significant layer of creosote has acc...

Страница 24: ...d by volume cords which means the energy per cord can differ widely among different species of wood In general hard woods like maple and oak are denser and have more energy per piece than soft woods s...

Страница 25: ...be disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all coals have thoroughly cooled Do not place other waste materials in the ash con...

Страница 26: ...s before installation or removal 3 To install slide the tube into the right hand side hole as far as possible and then bring it back into the hole on the left hand side lining up the relief or notch c...

Страница 27: ...halves of the lightweight baffle plates overlapping them and making sure they are pushed back as far as they can go Photo 4 NOTE Only Photo 4 shows the spring retainers installed 1 2 3 4 NOTE Only us...

Страница 28: ...door seal can have a significant effect of the performance and durability of the fireplace A poorly adjusted door can result in reduced efficiency excessive wood consumption and premature insert fail...

Страница 29: ...n on your work surface making sure the handle hangs over the edge so the door lays flat on a soft surface 4 Remove the 8 bolts holding the glass retainer to the door and remove the glass 5 Install the...

Страница 30: ...Chalet 1800 Ins 30...

Страница 31: ...KS REFER TO PAGE 26 FOR REQUIRED BRICK 18 780 0034 GLASS RETAINER 8 SCREWS REQUIRED P 300 2015 NOT SHOWN 19 314 0004 GLASS GASKET 3 4 GRAPHITE FLAT FIBER GLASS GASKET 20 307 0057 REPLACEMENT GLASS 14...

Страница 32: ...oblem Description NOTE Warranty may be void if work is carried out by an unqualified person s Only original Archgard parts may be used Please consult your Archgard dealer or representative if in doubt...

Страница 33: ...LONG LINE CUT ALONG LINE CUT ALONG LINE Model CHALET 1800I Serial Date Installed Name Address City State Prov ZIP Phone _____ Dealer s Name Address City State Prov ZIP Phone _____ Installer s Name Add...

Страница 34: ...Chalet 1800 Ins 34...

Страница 35: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Страница 36: ...esigned with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thor oughly before it leaves our door Archgard is pleased to extend this Li...

Отзывы: