BEFORE INSTALLING AND USING THIS APPLIANCE
.
The installation of Smoke and Carbon Monoxide detectors along with a minimum of a five pound
fire extinguisher is highly recommended in any home .
When you first fire up your CHALET 1800 WOOD Fireplace Insert, you may notice the smoke de-
tectors operating more frequently. This may be due to the curing of stove paint or oils from manu-
facturing or fumes caused by accidentally leaving the door open. Do not disconnect the detectors.
Consult local building or fire officials about restrictions and installation inspection and permit re-
quirements in your area.
Let your home insurance company know that you plan to install this CHALET 1800 WOOD Fire-
place Insert in your home.
Please read this entire manual before you install and use this CHALET 1800 WOOD Fireplace In-
sert in your home. Failure to follow instructions may result in property damage, bodily injury or
even death.
Install and use only in accordance with manufacturer’s installation and operating instructions.
Have the chimney & fireplace inspected and swept prior to installing the CHALET 1800 WOOD
Fireplace Insert to be sure that the chimney/fireplace meets local requirements for construction
and clearances for Chimneys and Fireplaces and/or N.F.P.A. 211
Standards in the USA and Pro-
vincial Building codes and CSA B365 - Installation Code for Solid Fuel Appliances in Canada or
any other applicable local code requirements and is OK to have an insert installed into it and also
ensure that the flue is free of creosote.
Do not connect the insert to a chimney system servicing another appliance
The chimney damper may be removed to install the chimney liner. Check local codes first
If using a Direct Connect, a means must be provided for removal of the insert to clean the chimney
flue.
If using a Direct Connect, a clean-out door may be required, by your Authority having Jurisdiction
A permanent metal warning label must be attached to the back of the fireplace stating that the fire-
place may have be altered and may be unsafe to use without the insert.
Do not use unlabelled parts, or substitute parts made for another chimney system .
Install only to liner/chimney manufacturer's installation instructions.
The chimney must be suitable for wood burning use.
Check for creosote build up or other obstructions.
Inspect your chimney for cracks, loose mortar or
other physical defects, if any are found, use the full
liner method of installation, do not use the blocker
plate or Direct Connect method.
RECOMMENDED
MINIMUM CHIMNEY
HEIGHTS
The chimney must be at least 3 ft. (.9m) higher
than the highest point where it passes through the
roof and at least 2 ft. (.6m) higher than the highest
part of the roof or structure within 10 ft. (3m) of the
chimney, measured horizontally.
These are code
requirements and cannot guarantee a suitable
draft.
We recommend using a minimum total sys-
tem height of 12 ft. (3.6m), measured from the flue
collar to the bottom of the chimney cap)