Archgard 72-DVTE30N-2 Скачать руководство пользователя страница 56

72-DVTE30-2 

  

 

 

 

56

 

 

 

 

 

 

This Limited Warranty is made by ARCHGARD INDUSTRIES LTD., hereinafter referred to as 

Archgard

”.  

Archgard warrants to the original purchaser of an 

Archgard gas burning fireplace(s) that the product will be free from defects in materials and workmanship under normal use and service, for a 

lifetime

”. 

All war-

ranty repairs are to be performed by an authorized Archgard Dealer during the warranty period. Other repair / service company charges for any work done 

during the warranty period, will be the responsibility of the home owner.

 

 

INCLUSIONS: 

LIFETIME LIMITED WARRANTY

 

All heat exchangers, combustion chamber, burner tubes and pans

 

Ceramic Fiber Logs and Ceramic Brick Panels, against splitting and cracking

 

 

NOTE

: Discoloration and some minor movement of certain parts are normal and are not a defect; therefore, not covered under warranty.

 

 

The above will be covered under 

Parts & Labour

” 

to the original purchaser for five (5) years and 

Parts Only

” 

thereafter from original date of purchase.

 

 

INCLUSIONS: 

TWO YEAR LIMITED WARRANTY

 

Ceramic Glass against thermal breakage

 

All 24K gold trims and accessories against tarnishing

 

All trim accessories against tarnishing and paint defects

 

 

The above will be covered under 

Parts & Labour

” 

to the original purchaser for two (2) years and 

Parts Only

” 

thereafter from original date of purchase.

 

 

INCLUSIONS: 

ONE YEAR LIMITED WARRANTY

 

Blowers, fans and fan motors, wiring, rheostats and thermodiscs

 

Rocker switches, spill switches and wiring to them

 

Gas control valves, pilot assemblies including thermopiles, thermocouples, electrodes and igniters

 

Tempered Glass is under warranty for ONE year to the original purchaser from date of purchase

 

 

The above will be covered under 

Parts & Labour

” 

to the original purchaser for one (1) year from date of purchase.

 

 

EXCLUSIONS:

 

Travel time or mileage to original purchaser

s residence.  Archgard suggests that you pre

-

arrange travel expenses with your Authorized Archgard Dealer.

 

 

WHAT TO DO IN THE EVENT OF A PROBLEM:

 

Thoroughly read your 

Owner

s Installation, Operation & Maintenance Manual

 

If you cannot solve the problem, contact your Archgard dealer or representative

 

When calling for assistance, please have the following information:

 

Model of your fireplace

 

Serial Number

 

Place of Purchase

 

Date of Purchase

 

Problem Description

 

 

NOTE

: Warranty will be void if work is carried out by an unqualified person(s).  Only original Archgard parts may be used.  Please consult your Archgard dealer 

or representative if in doubt about a replacement part(s).

 

 

All warranty repairs are to be performed by an authorized Archgard Dealer during the warranty period. Other repair / service company charges for 

any work done during the warranty period, will be the responsibility of the home owner.

 

 

 

OBTAINING WARRANTY SERVICE:

 

The original purchaser shall return the defective part(s) to the original authorized Archgard dealer –

 

transaction prepaid, along with the serial number of the appli-

ance and original proof of purchase.  Any defective part, in our judgment, will be repaired or replaced at Archgard

s discretion.  The dealer must obtain approval 

from Archgard before any repairs are made.

 

 

WARRANTY LIMITATION: 

 

THIS LIMITED WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED AS TO QUALITY, MERCHANTABILITY 

OR FITNESS FOR PARTICULAR PURPOSE.

 

 

The appliance is only warranted for the use as intended by the installation and operating instructions and local building codes.  The warranty will not cover dam-

age due to accident, misuse, abuse, alteration, improper installation or 

Acts of God

”.  

This limited warranty is void unless the appliance is installed by a qualified 

installer, in accordance with the instructions furnished with the appliance.  Some Provinces or States do not allow limitations on how long an implied warranty 

lasts, so the above limitations may not apply to the original purchaser.  Any damage resulting from defects in this product is limited to the replacement of the 

defective part(s) and does not include incidental and consequential exposures sustained in connection with the product.  This includes facing(s), mantle(s), cabinet

(s), tile(s) or any other finishes resulting from removal of any gas appliance.  This warranty is limited to residential use only and gives the consumer specific 

rights.  These rights may vary from State to State or Province to Province.

 

ARCHGARD LIMITED WARRANTY

 

Содержание 72-DVTE30N-2

Страница 1: ...supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN...

Страница 2: ...Instructions CAUTION 34 Final Installation Check and Initial Operation 35 Lighting Instructions on Rating Plate 36 Glass Door Removal and If your Glass Breaks 37 Safety Barrier Installation 38 Louver...

Страница 3: ...climates the glass door or the front of the fireplace could become very cold to the touch Dynamic Start Advantage will solve most problems experienced by older IPI operated fireplaces Please complete...

Страница 4: ...72 DVTE30 2 4 RATING PLATE SAMPLE...

Страница 5: ...n Terminations installed and sealed in compliance with local building code Direct vent termination is highest point in vent assembly Wiring Electrical YES IF NO WHY NOT Connected to household 110 120v...

Страница 6: ...quids near the appliance Clothing or other flammable material should not be placed on or near the appliance WARNING Do not operate appliance with the glass front removed cracked or broken Removal of t...

Страница 7: ...ocal codes or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 We recommend that our gas hearth products be installed and se...

Страница 8: ...piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 5 kPa Failure to do so will dama...

Страница 9: ...5 mm to side of faceplate MANTLE see diagram VENT 1 25 mm to outside side and bottom surface 2 50 mm to outside top surface CLEARANCES TO COMBUSTIBLES FRONT VIEW DIMENSIONS A 31 787 mm B 6 152 mm C 3...

Страница 10: ...re acceptable 6 152 mm projection Mantle may start 39 990 mm and above Minimum Height from Top of Surround 14 356 mm from front top of appliance to a 6 152 mm mantle Minimum Height From Bottom of Appl...

Страница 11: ...ay be added to the back of the fireplace top nailing flange after the fireplace is installed Dimensions A 38 965 mm B 16 412 mm C 38 965 mm TERMINATION FRAMING H I NOTE Be sure to include 6mm rise per...

Страница 12: ...le or other combustible materials other than wood flooring the appliance must be installed on metal or wood panel extending the full width and depth of the appliance VENT TERMINATION LOCATIONS ALLOWAB...

Страница 13: ...center line of the terminal M Clearance under veranda porch deck or balcony 12 inches 30 cm E Clearance to unventilated soffit F Clearance to outside corner G Clearance to inside corner 9 22 5cm 9 22...

Страница 14: ...venting charts given in this manual Use vent spacers between the inside 4 101mm and outside 7 178mm vents at 3 ft 915mm intervals Archgard Direct Vent System ONLY Never slope horizontal vents downwar...

Страница 15: ...equired if the vent system is between 10 18 and Re strictor Number 2 below is required if the vent system exceeds 18 Installing them under any other circumstances may cause hazardous venting condition...

Страница 16: ...y Archgard or Simpson Dura Vent direct vent systems with Archgard 999 DV SDA adapter Please strictly follow the venting instructions for optimum performance from the appliance and to avoid sooting and...

Страница 17: ...elbows as outlined in the Venting Chart necessary to reach from the Appliance adaptor 999 DV SDA Ensure that all Simpson Dura Vent and or flexible gas liners are connected and sealed accordingly 5 Cu...

Страница 18: ...storage spaces or closets which the vent must pass through must be enclosed Flat to 7 12 2 Feet 0 61 Meters Over 7 12 8 12 2 Feet 0 61 Meters Over 8 12 9 12 2 feet 0 61 Meters Over 9 12 10 12 2 5 Feet...

Страница 19: ...inlet apply a bead of high temperature sealant ap proximately 6mm wide Slide the 4 101mm pipe onto the appliance and secure with 3 screws evenly spaced to the outlet Repeat the procedure at the termi...

Страница 20: ...ONTALLY USING FLEXIBLE DIRECT VENT SYSTEMS VENT KIT COMPONENTS TVK 1 Horizontal Termination Cap 7 mm 4 100mm flexible liner Sleeve Firestop Sealant Screws Spring spacers NOTE Pitch the flexible pipe u...

Страница 21: ...mination cap faces up and fasten the termination head to the wall with 4 screws provided with the kit NOTE If installing the termination head to vinyl or wood siding a Vinyl Siding Deflector 999 DV V...

Страница 22: ...ps Minimum components required for horizontal termination using Simpson Dura Vent 1 999 DV SDA Appliance adaptor 1 90 Deg Elbow 1 Horizontal Termination Cap 1 Wall Thimble 1 Length of pipe for top of...

Страница 23: ...e NOTE Twist lock procedure Four inden tations located on the female ends of the pipes and fittings are designed to slide straight onto the male ends of adjacent pipes and fittings by orientating the...

Страница 24: ...rmination cap NOTE The four wood screws provided should be replaced with the appropriate fasteners for stucco brick concrete or other types of siding For buildings with VINYL SIDING a Vinyl Siding Sta...

Страница 25: ...anel Run the line into the left side of the appliance through the hole in the rear of the junction box and hold with a standard 7 8 22 mm clamp Connect the black supply conductor to the free black con...

Страница 26: ...rized Archgard Dealer Gas and vent connections must be made before installing the logs and embers on the pan burner NOTE Improper placement of logs and or embers may cause sooting on the internal part...

Страница 27: ...Continued Step 2 Locate Log with 7201 stamped on the bottom and place it as shown Step 1 Locate Log with 7207 stamped on the bottom and place it as shown 7207 7201 IMPORTANT Back of log 7201 must rest...

Страница 28: ...2 28 Step 3 Locate Log with 7203 stamped on the bottom and place it at the rear as shown Step 4 Locate Log with 7202 stamped on the bottom and place it on the burner as shown LOG PLACEMENT Continued...

Страница 29: ...DVTE30 2 29 LOG PLACEMENT Continued Step 5 Locate Log with 6 stamped on the bottom and place it on the front pins as shown Step 6 Locate Log with no number stamped on the bottom and place it as shown...

Страница 30: ...ep 6 Locate Log with 7205 stamped on the bottom and place it on the front pins as shown Step 7 Place black embers around logs as shown do not cover the holes in the burner 7204 Black embers Grate Step...

Страница 31: ...broken or damaged logs The fireplace has panel mounting brackets already in place Remove the brackets before in stalling the panels Locate the brick or reflective panels and place them in the firebox...

Страница 32: ...wn will result in flame im pingement causing sooting of the logs brick liner and ceramic glass viewing area Right Brick Panel Placement as Shown 2nd Panel 3rd Panel Use existing screws to secure brick...

Страница 33: ...OTE Installing the panels in any other position other than shown will result in flame im pingement causing sooting of the logs brick liner and ceramic glass viewing area Left Brick Panel Placement as...

Страница 34: ...et to OFF to allow paint to cure after the installer has checked to ensure the fan is operational Smoke and fumes caused by the curing process may cause discomfort to some individuals FIRST FIRE 1 BEF...

Страница 35: ...tomer the installer must ensure that the appliance is firing correctly and that the electrical system is in working order This will include 1 Performing leak tests of supply line gas control valve sup...

Страница 36: ...72 DVTE30 2 36 LIGHTING INSTRUCTIONS ON RATING PLATE...

Страница 37: ...damaged Replacing the Glass Door Reverse the above procedure WARNING Do not operate appliance with the glass front removed cracked or broken Replacement of the glass should be done by a licensed or q...

Страница 38: ...72 DVTE30 2 38 If barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance Part Number 72 BS BARRIER SCREEN INSTALLATION AND REMOVAL...

Страница 39: ...cate the Upper Louver Fig 1 2 Ensure the glass door is on the appliance 3 Place the louver in the two catches located at the side of the appliance Lower Louver installation 1 Locate the Lower Louver F...

Страница 40: ...tart with a little bit of tinder and kindling to create small fire and then work your way up to larger logs once a draft has been established Dynamic Start uses the same principle When you press the O...

Страница 41: ...72 DVTE30 2 41 REMOTE CONTROL SETUP AND OPERATION SIMPLE INSTALLATION Optional handheld remote...

Страница 42: ...NG INSTALLATION OR MAINTENANCE OF THE RE CEIVER DEVICE TURN OFF MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE BATTERIES IN CASE OF REMOTE CONTROL MALFUNCTION TURN OFF THE FIREP...

Страница 43: ...72 DVTE30 2 43 REMOTE CONTROL SETUP AND OPERATION cont Fig 3 Battery compartment...

Страница 44: ...72 DVTE30 2 44 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 45: ...72 DVTE30 2 45 REMOTE CONTROL SETUP AND OPERATION cont Not available on all units...

Страница 46: ...n burner is not turned on for seven continuous days the pilot will turn itself off When the main burner is lit again the cycle repeats The pilot will remain lit for seven days even after the main burn...

Страница 47: ...s recommended you use a vacuum cleaner to clean off any dust or lint Vacuum and clean any lint accumulations or debris in the firebox on the burners on the pilot at the primary air opening on the conv...

Страница 48: ...t parts must be authorized by Archgard for suitability Caution Wear gloves when adjusting the primary air with the appliance hot Note the Shutter is set at the factory and normally only requires reset...

Страница 49: ...ir Sleeve fully toward the left This will allow the sleeve to disconnect from the burner tube Follow ADJUSTING PRIMARY AIR instructions within this manual for reassembly 4 Remove the grate and front l...

Страница 50: ...gs 7 Check for leaks CHECKING INLET AND OUTLET GAS PRESSURE CHECKING AND ADJUSTING PILOT CONVERTIBLE PILOT ORIFICE The pilot assembly is convertible to the type of gas being used simply unscrew the bo...

Страница 51: ...Electrical code CSA C22 1 NOTES Ensure that the main power and breaker system is turned OFF before removing the fan Make sure the fireplace has been turned off and is cool to the touch Mark all wires...

Страница 52: ...D 301 0068 52 Orifice Main Burner Orifice Drill to 52 DMS 1 62 mm for Propane 1 EA E 308 6017 Sit 885 Electronic Gas Valve 1 EA G 308 0123 IPI Pilot Assembly Convertible NG LP 1 EA H n a Spark and Se...

Страница 53: ...Log 7203 1 EA 310 634720 4 Log 7204 1 EA 310 634720 5 Log 7205 there is only 5 on log 1 EA 310 634720 6 Log 7206 there is only 6 on log 1 EA 310 634720 7 Log 7207 1 EA 872 0060 R2 Grate 1 EA 872 0053...

Страница 54: ...plete Replacement Door Includes glass gasket and door frame Black Square Door Assembly 1 EA 813 0076 Complete Replacement Door Includes glass gasket and door frame Black Arch Door Assembly 1 EA Replac...

Страница 55: ...Qty Unit 72 BRPL QCR 2 Ceramic Brick Panel Set 1 ST 702 0044 Brick Panel Clips 2 EA Brick Panel Kit Quebec City Grey 72 BRPL QCG 2 Complete Brick Panel Set 1 EA Brick Panel Kit Reflective Glass 72 BR...

Страница 56: ...roblem contact your Archgard dealer or representative When calling for assistance please have the following information Model of your fireplace Serial Number Place of Purchase Date of Purchase Problem...

Страница 57: ...ace completes its heating function You will likely hear these same sounds more on start up and shut down This is normal for steel fireplaces Q When my appliance is OFF and my pilot light is lit I hear...

Страница 58: ...Why did you choose this product Thank you for purchasing our product and filling out this warranty card Save time by completing this form at www archgard com warranty registration mm dd yyyy POSTAGE...

Страница 59: ...72 DVTE30 2 59 NOTES...

Страница 60: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Отзывы: