MAINTENANCE
Cleaning and Routine Maintenance
The exterior painted surfaces, glass, and metal plated trims may be cleaned with a soft, non
-
abrasive cloth and water
or a suitable, mild, non
-
abrasive cleaner. Be sure there are no fingerprints left on the glass panels as high tempera-
tures can bake these prints on permanently.
Regularly:
•
Frequent cleaning of the ceramic glass is recommended. We recommend using a good quality ammonia free gas
fireplace glass cleaner that is available at any hearth retail location. Take care to avoid scratching glass while
cleaning. DO NOT CLEAN WHILE HOT. Never use common household cleaners to clean the glass.
•
Keep the appliance area free from combustible materials, such as paper, wood, clothing, gasoline and flamma-
ble solids, liquids and vapors
•
Visually check the height and color of the burner and pilot flames
Once a year, have a qualified service technician:
•
Perform the regular services listed above
•
Inspect and operate the pressure relief mechanism (door buckles) to verify they are free from obstruction and
operate properly
•
Carefully remove the logs and gently brush off any loose carbon deposits. This job is best done outside the
house, wearing a dust mask. The logs are very fragile, take care not to break them. Do not wash logs with any
liquid. While the logs are removed, check that all burner openings are not obstructed and it is recommended you
use a vacuum cleaner to clean off any dust or lint
•
Vacuum and clean any lint accumulations or debris in the firebox, on the burners, on the pilot, at the primary air
opening, on the convection air blower and in any combustion and convection air passageways
•
After cleaning, the logs and embers must be replaced according to the instructions in this manual
•
Inspect the operation of the flame safety system pilot and gas valve
•
Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve opening.
Flames should match those shown in
Page 47
•
Completely inspect the appliance and the venting system, if the vent pipe or seal is found to be defective, re-
place and or reseal (follow the instructions found in the venting instructions in this manual)
•
Inspect the condition of the vent and vent terminal for sooting or obstruction and correct if present
•
Test and measure the flame failure response time of the flame safety system. It must de
-
energize the safety
shutoff in no more than 30 seconds
•
Check all accessible gas
-
carrying tubes, connections, pipes and other components for leaks
CAUTION:
Do not conduct maintenance on the appliance while it is operating or while it is still hot. Always verify proper
operation after servicing.
WARNING:
All parts removed or disturbed, including guards and grills, must be properly replaced after maintenance.
Service and repair must be conducted by a qualified service person. If these instructions are not followed, a fire
or explosion may result, causing property damage, personal injury or loss of life.
Содержание 72-DVTE30N-2
Страница 4: ...72 DVTE30 2 4 RATING PLATE SAMPLE...
Страница 36: ...72 DVTE30 2 36 LIGHTING INSTRUCTIONS ON RATING PLATE...
Страница 41: ...72 DVTE30 2 41 REMOTE CONTROL SETUP AND OPERATION SIMPLE INSTALLATION Optional handheld remote...
Страница 43: ...72 DVTE30 2 43 REMOTE CONTROL SETUP AND OPERATION cont Fig 3 Battery compartment...
Страница 44: ...72 DVTE30 2 44 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 45: ...72 DVTE30 2 45 REMOTE CONTROL SETUP AND OPERATION cont Not available on all units...
Страница 59: ...72 DVTE30 2 59 NOTES...
Страница 60: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...