37
GLASS DOOR REMOVAL
WARNING:
Do not attempt to remove the glass door when the appliance is hot.
1.
Remove the top louver by pulling the entire louver assembly towards you.
2.
Open bottom hinged louver .
3.
Locate the 2 buckle latches under the door frame (Fig.1) and pull down the lever on the
back of the latches to release them.
4.
Unhook the latches from the bottom of the door and swing the bottom of the door
towards you then lift up on the whole door to unhook the top of door. Carefully remove
the door and put it away at a safe location where it cannot be scratched or damaged.
Replacing the Glass Door
Reverse the above procedure.
WARNING
: Do not operate appliance with the glass front removed, cracked or broken.
Replacement of the glass should be done by a licensed or qualified service person. Do not
abuse the glass doors, such as striking or slamming shut.
Buckle latch
Buckle latch
Top of door
hooks onto
fireplace
Fig. 1.
IF YOUR GLASS BREAKS
In
the event your glass cracks or breaks, Archgard recommends that a new door assembly be
ordered to replace the original door.
•
Remove door as per the instructions above.
•
Replace with new door assemblies.
NOTE: the NEW door will omit some odor when the appliance is re
-
lit and the odor will dissipate
after the gasket material within the door has cured.
WARNING:
Do not not substitute any glazing material types.
Содержание 72-DVTE30N-2
Страница 4: ...72 DVTE30 2 4 RATING PLATE SAMPLE...
Страница 36: ...72 DVTE30 2 36 LIGHTING INSTRUCTIONS ON RATING PLATE...
Страница 41: ...72 DVTE30 2 41 REMOTE CONTROL SETUP AND OPERATION SIMPLE INSTALLATION Optional handheld remote...
Страница 43: ...72 DVTE30 2 43 REMOTE CONTROL SETUP AND OPERATION cont Fig 3 Battery compartment...
Страница 44: ...72 DVTE30 2 44 REMOTE CONTROL SETUP AND OPERATION cont...
Страница 45: ...72 DVTE30 2 45 REMOTE CONTROL SETUP AND OPERATION cont Not available on all units...
Страница 59: ...72 DVTE30 2 59 NOTES...
Страница 60: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...