59
Maintenance
18.15 Replacing the Fan
Before you begin:
•
Ensure the fireplace is off and cool before servicing
• Ensure the gas supply is turned OFF and disconnect the power supply (including backup batteries)
•
Open the Control Access Door (see
Section 6.4
)
Step 2:
Remove the (5) 1/4" tek screws securing the fan bracket
to the back of the fireplace.
Step 1:
Unplug the fan wires from the control board.
Figure 18.15.01:
Figure 18.15.02:
CAUTION:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing. This appliance, when installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code,
CSA C22.1
.
Step 3:
Pull the fan from the back of the fireplace.
Figure 18.15.03:
Step 4:
Carefully route the fan wire up through the opening in the
bottom of the fireplace.
Figure 18.15.04: