57
Maintenance
18.14 Replacing the Gas Valve
Step 2:
Unplug the colored wires from the valve.
Figure 18.14.02:
Before you begin:
•
Ensure the fireplace is off and cool before servicing
• Ensure the gas supply is turned OFF and disconnect the power supply (including backup batteries)
•
Open the Control Access Door (see
Section 6.4
)
Step 3:
Unplug the valve motor from the control board.
Figure 18.14.03:
CAUTION:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing. This appliance, when installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code,
CSA C22.1
.
Step 4:
Use a 7/16" wrench to remove the pilot line from the
valve.
Figure 18.14.04:
Step 1:
Disconnect the gas supply line from the inlet at the back
of the fireplace.
Figure 18.14.01: