Archgard 45-DVFE28LN-1 Скачать руководство пользователя страница 48

48

Maintenance

18.2  Servicing Under Warranty

All service work under warranty must be conducted by a qualified Archgard service technician. Before servicing, read the terms and 

conditions of the warranty at the back of this manual. Contact the authorized Archgard dealer where you purchased the appliance from 

and provide them with details of the problem, along with the initial installation information (from the front of this manual).  

WARNING: 

Servicing of this appliance 

must be conducted by a qualified Archgard service technician

. Improper servicing, 

adjustment or alteration of this appliance may cause property damage, personal injury or loss of life. All servicing should 

be conducted with the appliance cold. All replacement parts must be authorized by Archgard for suitability.

18.3  Checking Inlet and Outlet Pressure

1. 

Remove the surround.

2. 

The pressure test taps are located on the valve's front face. The inlet is marked "

IN

" and the outlet is marked "

OUT

". See 

Figure 

18.3.01

3. 

Loosen the set screw inside the tap with a 3/16" flathead screwdriver.

4. 

Connect a 1/4” (6 mm) rubber tube to the tap post and a manometer.

5. 

Verify that the readings obtained are within specs (as shown on the appliance rating label)

6. 

Be sure to tighten the set screw inside the tap after you have finished taking pressure readings.

7. 

Check for leaks.

18.4  Checking and Adjusting Pilot

The flame should not have yellow tips but should engulf the flame 

sensor and spark electrode. It can be adjusted be turning the screw 

marked “pilot” on the control valve (See 

Figure 18.3.01

).

It may be necessary to remove the pilot cover for a better view of the 

pilot flame (see next page).

The pilot flames should have the characteristics shown in 

the illustration to the right.

Figure 18.3.01

Figure 18.4.01

Figure 18.4.02

IN

PILOT

OUT

Содержание 45-DVFE28LN-1

Страница 1: ...ype of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used INSTALLATION OPERATION AND MAINTENANCE MANUAL Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use an...

Страница 2: ...cking Procedure 26 13 2 Supplying Gas 27 14 0 Conversion Kit Instructions 28 14 1 Prepare the Fireplace 28 14 2 Pilot Conversion 28 14 3 Convert the Gas Valve 29 14 4 Complete the Conversion 29 15 0 Firebox Liner Installation 30 15 1 Brick Panel Installation 30 15 2 Reflective Glass Installation 32 16 0 Log Set Installation 34 17 0 Operation 38 17 1 Before Lighting 38 17 2 First Fire 38 17 3 Light...

Страница 3: ...m is the latest in fireplace technology It helps to create a better draft better flame appearance less condensation on the glass and years of carefree operation See Section 17 4 for complete explanation of how the system works Multiple Electronic Pilot Settings This fireplace uses a gas control valve that is operated by a Multifunction Remote Control It can be set up as either an Intermittent Pilo...

Страница 4: ...WARNING Do not operate appliance with the glass front removed cracked or broken Removal of the glass should be done by a licensed or qualified service person Do not to strike or slam the glass Any safety screen or guard removed for servicing an appliance must be replaced prior to operating Installation and Repair should be done by a qualified service person The appliance should be inspected before...

Страница 5: ... B149 1 in Canada Electrical connections and grounding must conform with local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists 3 3 Specifi...

Страница 6: ...opane Installation Codes CSA B149 1 Electrical connections and grounding must be in accordance with local codes if any if none follow the current CAN CSA C22 1 in Canada and ANSI NFPA 70 in the US This appliance is certified for installation in a bedroom or a bed sitting room This appliance is only for use with the gas indicated on the rating plate and may be installed in an aftermarket permanentl...

Страница 7: ...on horizontal run Terminations installed and sealed in compliance with local building code Direct vent termination is highest point in vent assembly Wiring Electrical Section 7 0 YES IF NO WHY NOT Connected to household 110 120v per local codes Unit is properly grounded Gas Section 13 0 YES IF NO WHY NOT Proper appliance for fuel type Was a conversion performed Leak check performed inlet and manif...

Страница 8: ... The rating labels are affixed to the side door panels see Section 6 5 The fan is located in the back of the firebox and may be accessed by removing the panel located behind the fireplace Note This manual uses images of an unpainted fireplace for the purposes of illustration Left and right side references in this manual correspond with the sides identified in Figure 6 1 01 Figure 6 1 01 Control Ac...

Страница 9: ...ntly pull the bottom of the screen outward and lift the screen off the screen retainer tabs located on the top of the glass door Figure 6 2 01 Figure 6 2 02 Installation To install the screen hook the top of the screen onto the screen retainer tabs located on top of the glass door and slip the tension tab on the bottom of the screen under the glass door frame Figure 6 2 03 Figure 6 2 04 Figure 6 2...

Страница 10: ...r to clear the upper part of the hinge Installation is the reverse of removal Figure 6 3 03 Figure 6 4 04 If Your Glass Breaks In the event your glass cracks or breaks replace the original door assembly with Archgard replacement door assembly part number RP 845 0000 The glass door and frame assembly must be replaced as a complete unit Remove the barrier screen See Section 6 3 and remove door as pe...

Страница 11: ...ntrol Board Gas Valve 6 5 Rating Label Location The rating label is located within the side doors of the fireplace The English label is located on the left side door and the French label is located on the right side door See the rating label sample in Section 4 0 To access open the door Caution Allow the fireplace to cool before opening the side doors Figure 6 5 01 Battery Holder ...

Страница 12: ...t side of the fireplace see Section 6 1 Do not cut or remove the grounding prong from the main power supply plug CAUTION Label all wires prior to disconnection when servicing NOTE This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical code CSA C22 1 ...

Страница 13: ...5cm 27 384in 21 34cm 8 401in Side View 69 61cm 27 405in 74 47cm 29 321in 77 46cm 30 497in 79 82cm 31 424in 68 20cm 26 852in 41 59cm 16 375in 28 14cm 11 080in 49 24cm 19 385in 29 50cm 11 614in 48 05cm 18 917in 43 82cm 17 251in 45 20cm 17 794in 34 53cm 13 596in 21 34cm 8 401in 69 55cm 27 384in 48 05cm 18 917in Top View Front View 48 05cm 18 917in 43 82cm 17 251in 45 20cm 17 794in 34 53cm 13 596in 69...

Страница 14: ...e panel set Many options are available from your local Archgard dealer 8 Install the logs glass door assembly and barrier screen 9 Verify proper operation of fireplace and all components PLACEMENT CLEARANCE REQUIREMENTS This fireplace must be installed on a level surface capable of supporting the fireplace and venting Due to high surface temperatures fireplace should be located out of traffic and ...

Страница 15: ...talled 2 45º degree elbows may be used in place of 1 90º elbow Always maintain a minimum 12 305 mm span between each 90º bend in the vent run Horizontal sections require 1 4 6 mm rise for every 12 305 mm of travel IF INSTALLING FLEX PIPE SYSTEMS More than a 30 degree bend constitutes a 45 degree elbow More than a 45 degree bend constitutes a 90 degree elbow More than a 90 degree bend is not permis...

Страница 16: ...ollar Flashing Combination to Roofline Flex Venting Rigid Venting Flex to Rigid Adapter Part Number Description 45 TVKFS Top Vent Kit 999 DV VSD Vinyl Siding Deflector 999 DV HTC Horizontal Termination Cap 999 DV STC Snorkel Termination Cap 999 DV SCU Termination Safety Cage Universal 143 4 W x 143 4 H x 101 4 D Archgard Flex Vent Kits 999 DV FL4710 Includes 4 7 aluminum flex liner 10 long with si...

Страница 17: ...T 1 OF 1 WEIGHT DVA 48in Pipe FINISH MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 32 TWO PLACE DECIMAL 015 THREE PLACE DECIMAL 005 ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE CHECKED DRAWN DATE NAME 8 24 2017 PROPRIETARY AND CONFIDENTIAL U R D Prototype CADD Duravent Pipe DVA 48in Pipe Thursday August 24 2017 9 05 20 AM SCALE 1 20 SIZE DWG NO A REV SHEET 1 OF 1 WEIGHT DVA 48...

Страница 18: ... 2 to 15 1 2 Long Adjustable 4DT TL38 38 to 70 46DVA 24TA 15 1 2 to 22 1 2 4DLA30 16 1 2 to 29 4 x 6 5 8 Hard Elbows 30 degree 94620630 46DVA E30 45 degree 94620645 4DT EL45 46DVA E45 4DE45 4D45L 60 degree 94620660 46DVA E60 90 degree 94620690 4DT EL90S 46DVA E90 4DE90 4D90L Slip 90 Degree Elbow 4DE90S Wall Strap 949164 4DTWS B 46DA WS 4WS 4DWS Elbow Offset Strap 949264 4DT OS 46DVA ES 4OS 4DWS Wa...

Страница 19: ... 46DVA HC S Horizontal Square Termination Copper 940164PYDC 46DVA HC C Horizontal Termination Other 940164 TM 4DHT Horizontal Round Termina tion Aluminum 4DT HCR 46DVA HRCS 4DHC Snorkels 14 Snorkel 94040614 4DT ST14 46DVA SNK14 4ST14 4D14S 36 Snorkel 94040636 4DT ST36 46DVA SNK36 4ST36 4D36S Horizontal High Wind Guard 940164SHRD 46 DVA WG 4DHWS Horizontal Safety Cage 94016SHRD Vertical Termination...

Страница 20: ...20 Installation 10 4 Termination Location Clearances N O Approved vent pipe Approved cap Figure 10 4 01 Figure 10 4 02 L V X Vent terminal Air supply inlet Area where terminal is not permitted Legend ...

Страница 21: ...rance above paved sidewalk or driveway located on public property 7 2 13 m M Clearance under veranda porch deck or balcony 12 305 mm N Minimum clearance from roof to lowest discharge opening 18 457 mm 18 457 mm O Clearance from vertical vent to adjacent wall 24 610 mm 24 610 mm Notes 1 In accordance with the current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance with the curr...

Страница 22: ...90 elbows Ensure there is enough vertical venting to accommodate the number of elbows used run refer to Section 10 2 If the snorkel termination is installed below grade IE basement proper drainage must be provided to prevent water from entering the snorkel termination see Figure 10 5 01 Do not attempt to enclose the snorkel termination in the wall or any other type of enclosure Do not locate snork...

Страница 23: ...less of venting manufacturer Item Critical Dimensions Distance from ceiling to horizontal pipe 2 5 08 cm Thimble framing dimensions 9 22 86 cm W x 10 25 4 cm H Ceiling height and the height to the bottom of the thimble shown are based on a minimum vent run These values may vary depending on the requirements of each installation Figure 11 1 01 IMPORTANT WARNING Vent cap location must be in complian...

Страница 24: ...th this appliance may result in property damage or personal injury or loss of life 60 96cm 24 000in Minimum clearance required to top of the applianace and to a combustible material 2 54cm 1 000 Minimum to Side of Vent 5 08cm 2 000 Minimum to Top of Vent 10 16cm 4 000in Minimum Clearance 2 54cm 1 000 Minimum to Bottom and Sides of Vent Figure 12 1 01 12 1 Ceiling Clearance ...

Страница 25: ...cm clearance from the side of the fireplace to sidewalls Maintain a minimum of 4 10 16 cm clearance from the back of the fireplace to the wall behind the fireplace 10 16cm 4 000in 10 16cm 4 000in 12 3 Corner Installation Clearances Figure 12 3 01 Maintain a minimum of 4 10 16 cm clearance from the 45 corner of the fireplace to sidewalls ...

Страница 26: ...age is not covered by the manufacturer s warranty Natural Gas Pressure Settings The inlet supply or line pressure must be a minimum of 5 0 W C 1 24 kPa and a maximum of 14 0 W C 3 48 kPa The orifice is a 38 DMS 2 59 mm drill size ELEVATION INPUT RATING 0 4500 ft 0 1372 M 28 000 BTU hr 8 2 kW 4500 ft 1372 M and above 28 000 BTU hr 8 2 kW less 4 per 1000 ft 305 M above sea level Please contact your ...

Страница 27: ...ower supply including backup batteries Step 1 Run the gas line to the rear right side of the fireplace Step 2 A 3 8 pipe is connected to the gas valve and extends outside the back side of the fireplace see Figure 13 2 02 Connect the gas line to the pipe and tighten Step 3 Turn on the gas to the appliance and check for leaks Figure 13 2 01 Gasline Figure 13 2 02 ...

Страница 28: ...aving jurisdiction for proper derating methods KIT NUMBERS 45 CKELP for LP gas and 45 CKENG for Natural Gas KIT INCLUDES Gas conversion label 303 0128 Burner orifice part number 301 0068 52 52 DMS for LPG part number 301 0068 38 38 DMS for NG Instruction Sheet SIT 885 Valve conversion kit c w instructions gas type label WARNING SHUT OFF GAS SUPPLY AND ELECTRICAL POWER TO FIREPLACE SHUT OFF GAS SUP...

Страница 29: ...ard the two 2 pressure regulator mounting screws A pressure regulator tower B and the spring and diaphragm assembly C If applicable 3 Ensure the rubber gasket D which is prefitted as part of assembly E is properly positioned see Figure 14 3 02 otherwise fit the gasket as shown Figure 14 3 02 4 Install the new STEPPER MOTOR pressure regulator assembly as shown in Figure 14 3 03 and Figure 14 3 04 U...

Страница 30: ...u begin Ensure the gas supply is turned OFF and disconnect the power supply including backup batteries Open the Glass Door with Barrier Screen attached see Section 6 4 Remove the log set if installed see Section 16 0 Step 4 Slip the lower brick clips over the screws that were loosened in Step 2 Figure 15 1 04 Step 1 Lift the secondary air channels from the burner Step 2 Loosen the 2 screws securin...

Страница 31: ...ed in the manual bag with the fireplace Figure 15 1 07 Step 8 Place the remaining side panel along the corresponding side of the firebox Figure 15 1 08 Step 9 Install the final upper panel clip to complete the installation Figure 15 1 09 Final Steps Install the secondary air channels that were removed in Step 1 Install the log set see Section 16 0 Close the Glass Door with Barrier Screen see Secti...

Страница 32: ...es can bake these prints on permanently Before you begin Ensure the gas supply is turned OFF and disconnect the power supply including backup batteries Open the Glass Door with Barrier Screen attached see Section 6 4 Remove the log set if installed see Section 16 0 Step 4 Place the other side panel along the remaining side of the firebox Figure 15 1 04 Step 1 Place the rear panel in the back of th...

Страница 33: ...pper panel clip to complete the installation Final Steps Make sure panels are clean Install the log set see Section 16 0 Close the Glass Door with Barrier Screen see Section 6 4 Resupply gas and power Light the fireplace to test the operation and flame appearance ...

Страница 34: ...mbers and logs on the burner CAUTION DO NOT block pilot opening with embers NOTE Improper placement of logs and embers may cause soot accumulation on the internal parts and glass This is not covered under warranty Do not use broken or damaged logs 16 0 Log Set Installation WARNING Failure to position the logs in accordance with the preceding diagrams or failure to use only parts specifically appro...

Страница 35: ...lace Log 2 over the locator pins in the back right corner of the firebox Figure 16 0 03 Step 4 Place a row of black embers in front of Log 1 and Log 2 Do not block burner ports or the pilot opening with embers Figure 16 0 04 Figure 16 0 05 Figure 16 0 06 Do Not Block Secondary Air Do Not Block Secondary Air Step 5 Make sure black embers are not blocking the secondary air under the secondary air ch...

Страница 36: ...Do not block the ports on the left side of the burner with the log Figure 16 0 09 Figure 16 0 10 Do Not Block With Log Step 9 Place black embers along the front of the burner and along the burner surround Do not block burner ports or the gap between the burner and burner surround Figure 16 0 11 Step 10 The platinum embers are located in the manual bag Pull the platinum embers apart Follow handling...

Страница 37: ... 1 310 6450 1 Log 1 Back Left 1 310 6450 5 Log 5 Middle Left 1 310 6450 2 Log 2 Back Right 1 310 0019 Platinum Embers 1 bag 1 310 6450 3 Log 3 Front Left 1 310 0020 Black Embers 2 cup bag 1 Figure 16 0 13 Log Install Overview 1 2 3 4 5 Step 11 Place the platinum embers randomly around the burner Do not block burner ports Figure 16 0 12 ...

Страница 38: ...iance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 4 This appliance is equipped with an ignition device which automatically lights the pilot and main burner when operating the remote control Each Archgard Gas Fireplace is checked and tested at th...

Страница 39: ... louver or trim 6 each RED BARS 1 ARRÊTEZ Lisez les instructions de sécurité sur la portion supérieure à droite de cette étiquette 2 Réglez le commutateur à distance sur OFF 3 Ouvrez persiennes inférieurs ou garnir 4 Coupez l alimentation électrique de l appareil 5 Vanne d isolement de gaz ouverte 6 Attendre cinq 5 minutes pour laisser échapper tout le gaz Reniflez tout autour de l appareil y comp...

Страница 40: ...u build a fire You start with a little bit of tinder and kindling to create small fire and then work your way up to larger logs once a draft has been established Dynamic Start uses the same principle When you press the ON button on the remote control the main burner will light and remain with a low flame for two minutes This will first establish a draft in the vent and slowly warm up the fireplace...

Страница 41: ... and informative LCD display A Mode Key is provided to index between the features and a Thermostat Key is used for on off or to index through the thermostat function Additionally a Key Lock function is provided ATTENTION TURN OFF THE MAIN GAS SUPPLY DURING INSTALLATION OR MAINTENANCE OF THE RECEIVER DEVICE TURN OFF MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE BATTERIES IN ...

Страница 42: ...isplay WARNING THE REMOTE AND RECEIVER ARE RADIO FREQUENCY DEVICES PLACING THE REMOTE IN OR NEAR METAL ENCLOSURES MAY REDUCE THE SIGNAL RANGE Handheld Remote optional Figure 17 5 02 Figure 17 5 03 Continuous Pilot on Demand ...

Страница 43: ...The IFC module will beep four 4 times to indicate that it has successfully synced with the remote Turn the fireplace OFF using the ON OFF button on the remote to complete initialization The remote will now control the fireplace 5 Install the provided four 4 AA batteries into battery back up holder Turn ON the Appliance With the system OFF press the ON OFF Key on the Remote The Remote display will ...

Страница 44: ...em is on but the flame is off the flame will activate in the high setting A single beep will confirm reception of the command This function is disabled when in SMART Thermostat Mode and does not operate in the first two minutes of operation during the Dynamic Start Advantage Fan Speed Control If the appliance is equipped with a hot air circulating fan the speed of the fan can be controlled by the ...

Страница 45: ...igure 17 5 09 Figure 17 5 10 Continuous Pilot on Demand Intermittent Pilot CPI IPI Selection With the system in OFF position press the Mode Key to index to the CPI mode icon Pressing the UP Arrow Key will activate the Continuous Pilot on Demand Ignition mode CPI Pressing the Down Arrow Key will return to IPI A single beep will confirm the reception of the command Figure 17 5 11 CPI vs IPI Continuo...

Страница 46: ... time To deactivate this function press the MODE and UP Keys at the same time Low Battery Power Detection Less than 4V Remote The life span of the remote control batteries depend on various factors Quality of the batteries used The number of ignitions of the appliance The number of changes to the room temperature set point etc When the Remote batteries are low a Battery Icon will appear on the LCD...

Страница 47: ...le take care not to break them Do not wash logs with any liquid While the logs are removed check that all burner openings are not obstructed and it is recommended you use a vacuum cleaner to clean off any dust or lint After cleaning the logs and embers must be replaced according to the instructions in this manual Vacuum and clean any lint accumulations or debris in the firebox on the burners on th...

Страница 48: ...Inlet and Outlet Pressure 1 Remove the surround 2 The pressure test taps are located on the valve s front face The inlet is marked IN and the outlet is marked OUT See Figure 18 3 01 3 Loosen the set screw inside the tap with a 3 16 flathead screwdriver 4 Connect a 1 4 6 mm rubber tube to the tap post and a manometer 5 Verify that the readings obtained are within specs as shown on the appliance rat...

Страница 49: ...air flow to the burner slide the air shutter to the left To close the air shutter and decrease air flow to the burner slide the air shutter to the right CAUTION Do not adjust primary air below specified opening on the rating label Figure 18 5 01 Lazy yellow flames Ideal Short blue flames Air shutter open too far Dark orange flames black tips Air shutter closed too far Excessive burner media Liftin...

Страница 50: ...om the firebox 9 Resupply gas and power 10 Turn the fireplace on and unplug the fireplace to test the backup batteries Battery Specifications 4 x AA Batteries 1 Disconnect power supply to the fireplace including backup batteries 2 Ensure the fireplace is off and cool before servicing 3 Turn off gas supply 4 Open the Control Access Door see Section 6 4 5 The control board is affixed to the bottom o...

Страница 51: ...codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical code CSA C22 1 1 Mark all the wires connected to the control board as you unplug them from the control board 2 Make sure you pull the 2 pin connector as shown in Figure 18 8 02 3 Plug the wires and the 2 Pin connector into the new control board 4 Place the new control board on the botto...

Страница 52: ...52 Maintenance 18 9 Wiring Schematic Blue IPI CPI Yellow APS On Off override jumper Ignition Pilot Flame sensor SW1 Botton red Sync button Figure 18 9 01 ...

Страница 53: ...backup batteries Open the door with barrier screen see Section 6 3 Remove the logset see Section 16 Remove the panel set if installed see Section 15 18 10 Removing the Baffle Step 1 Remove the 2 tek screws securing the baffle to the back of the firebox Figure 18 10 01 Installation is the reverse of removal Figure 18 10 02 Step 2 Remove the tek screw securing the left side of the firebox Figure 18 ...

Страница 54: ...rier screen see Section 6 3 Remove the logset see Section 16 Remove the panel set if installed see Section 15 18 11 Removing the Burner Surround Step 1 Lift and remove the secondary air channels Figure 18 11 01 Installation is the reverse of removal Figure 18 11 02 Step 2 Remove the 4 1 4 tek screws securing the burner surround Step 3 Lift the burner surround to remove from the firebox Figure 18 1...

Страница 55: ...ction 6 3 Remove the logset see Section 16 Remove the panel set if installed see Section 15 Remove the Burner Surround see Section 18 11 Open the Control Access Door see Section 6 4 Step 2 Remove the 2 tek screws securing the burner to the bottom of the firebox Figure 18 12 02 Step 3 Slide the burner to the right and lift to remove Figure 18 12 03 Step 3 Pull the air shutter from the mixing tube o...

Страница 56: ...p 4 Pull the control board from inside the pedestal Mark the wires and unplug them from the control board Figure 18 13 04 Step 5 Installation is the reverse of removal Replace the pilot gasket during install if necessary see Section 20 0 Make sure all wires are neat and tidy upon install Before you begin Ensure the fireplace is off and cool before servicing Ensure the gas supply is turned OFF and ...

Страница 57: ...igure 18 14 03 CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical code CSA C22 1 Step...

Страница 58: ...p 5 Pull the valve from the pedestal opening Reuse the brackets and fittings on the new valve Figure 18 14 05 Final steps Resupply gas to the fireplace Resupply power to the fireplace Light the fireplace and check for gas leaks fireplace operation and flame appearance See Section 17 and Section 18 5 Installation is the reverse of removal Organize wires neatly to avoid pinching or breaking wires du...

Страница 59: ...rd Figure 18 15 01 Figure 18 15 02 CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical...

Страница 60: ...to the fan Figure 18 15 06 Step 6 Unplug the wires from the fan Figure 18 15 06 Installation is the reverse of removal Organize wires neatly to avoid pinching or breaking wires during installation Final steps Resupply gas to the fireplace Resupply power to the fireplace Light the fireplace and check for fan operation and flame appearance See Section 17 and Section 18 5 ...

Страница 61: ...s supply is turned OFF and disconnect the power supply including backup batteries Open the Side Doors see Section 6 4 Step 1 Remove the 4 1 4 tek screws securing upper and lower grills at each side Step 2 Pull the grills away from the front of the fireplace Figure 18 16 01 Figure 18 16 02 Installation is the reverse of removal ...

Страница 62: ...board and is not damaged 4 Adjust pilot flame using the pilot adjustment screw if the pilot flame is too long or too short the flame should fully engulf the sensor rod and must be stable 5 Check supply pressure 6 Ensure the ground wire from the pilot is connected to the fireplace ground location The pilot was lit but will randomly go out 1 Turn the fireplace on again If the fireplace is in continu...

Страница 63: ... its heating function You will likely hear these same sounds more on start up and shut down This is normal for steel fireplaces Q I hear a click when my main burner turns ON or OFF A Your Gas Control Valve will make a clicking sound when it opens to allow gas to flow to the main burner This is a normal part of the operating system Q Can I burn wood and other materials in my gas fireplace A No Burn...

Страница 64: ...Fuse 3 15A 250V Pack of 5 EA 301 0068 38 Orifice 38 DMS 2 59 mm for Natural Gas EA 301 0068 52 Orifice 52 DMS 1 60 mm for Propane EA 308 0124 Pilot Assembly EA 314 0139 Pilot Gasket EA 301 6239 Pilot Gas Line EA RP 845 0040 Burner Assembly Log Burner EA 45 CKENG Conversion Kit LP to NG EA 45 CKELP Conversion Kit NG to LP EA 45 BRPL QCR Quebec City Red Brick Panel Set SET 45 BRPL QCG Quebec Cit Gre...

Страница 65: ... CLOSED Model 45 DVFE28LN 1 Serial Date Installed Name Address City State Prov ZIP Phone _____ Dealer s Name Address City State Prov ZIP Phone _____ Installer s Name Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card Save time by completing this form at www archgard com warranty registration ...

Страница 66: ...NOTES ...

Страница 67: ...e the problem contact your Archgard dealer or representative When calling for assistance please have the following information Model of your fireplace Serial Number Place of Purchase Date of Purchase Problem Description NOTE Warranty will be void if work is carried out by an unqualified person s Only original Archgard parts may be used Please consult your Archgard dealer or representative if in do...