72
Maintenance
18.16 Replacing the Light Bases
Before you begin:
•
Ensure the fireplace is off and cool before servicing
•
Ensure the gas supply is turned OFF and disconnect the
power supply (including backup batteries)
•
Remove the barrier screen (see
Section 6.3
)
•
Remove Glass Door (see
Section 6.4
)
•
Remove burner media (see
Section 16.0
)
•
Remove panel set (if applicable - see
Section 15.0
)
•
Remove the masking plate (see
Section 18.11
)
CAUTION:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing. This appliance, when installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code,
CSA C22.1
.
Step 2:
The back side of the baffle rests on two screws located in
the back of the firebox. Lift up and out to remove.
Step 1:
Remove the (5) 1/4" tek screws securing the baffle to the
top of the firebox and restrictor slider. Support the baffle to avoid
dropping it.
Figure 18.16.01:
Figure 18.16.02:
Step 4:
Remove the (2) 1/4" tek screws securing the light
deflector inside the fireplace. These screws also hold the front of
the light box in place
Figure 18.16.04:
Step 3:
Unplug the lights.
Left Side
Right Side
Figure 18.16.03:
Step 5:
Remove (2) remaining 1/4" tek screws and pull the light
base from the fireplace.
Figure 18.16.05:
Installation is the reverse of removal.