64
Maintenance
18.6 Replacing Batteries
18.7 Replacing Fuse
1.
Disconnect power supply to the fireplace (including back
-
up batteries).
2.
Ensure the fireplace is off and cool before servicing.
3.
Turn off gas supply.
4.
Remove the barrier screen (see
Section 6.3
).
5.
Remove the wire cover (see
Section 6.5
).
6.
Slide the sliding access door back and the control board out
(see
Section 6.5
).
7.
Remove the battery holder from the bottom of the control
board sliding bracket.
8.
Replace the batteries and tuck the battery holder behind the
wires on the bottom of the control board sliding bracket.
9.
Slide the control board in and close the sliding access door.
10.
Light the fireplace to verify proper operation. Resupply power
once fireplace operation has been confirmed.
11.
Replace the wire cover and barrier screen.
Battery Specifications:
4 x AA Batteries
1.
Disconnect power supply to the fireplace (including backup
batteries).
2.
Ensure the fireplace is off and cool before servicing.
3.
Turn off gas supply.
4.
Remove the barrier screen (see
Section 6.3
).
5.
Remove the wire cover (see
Section 6.5
).
6.
Slide the sliding access door back and the control board out (see
Section 6.5
).
7.
Remove the fuse holder from the control board.
8.
Replace the fuse with one which has the same specifications
using the existing fuse holder.
9.
Slide the control board in and close the sliding access door.
10.
Resupply power and light the fireplace to verify proper operation.
11.
Replace the wire cover and barrier screen.
Fuse type:
T3.15AL250V
Archgard Part Number:
RP-305-2080
Figure 18.6.01:
Figure 18.7.01: