6
General Information
4.0 Rating Plate
SAMPLE
Figure 4.0.01:
MODEL:
41-DVTE41LN-2
(SIT 885 Proflame)
DO NOT REMOVE THIS LABEL
LISTED VENTED GAS FIREPLACE HEATER and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES. Tested to: ANSI
Z21.88-2017 / CSA 2.33-2017, CSA 2.17-2017, CSA P.4.1-15 and CSA C22.2 No.3 - M1998(R.2014). This vented gas fireplace
heater is not for use with air filters. Certified for use in both CANADA and USA.
VENTED GAS FIREPLACE HEATER-NOT FOR USE WITH SOLID FUEL.
Manufactured as Natural Gas.
NG
LPG
Input rating
22,000 - 41,000 BTU/h
(6.45 - 12.02 kWh)
22,000 - 41,000 BTU/h
(6.45 - 12.02 kWh)
Manifold Pressure
1.1 - 3.8 in. W.C.
(0.27 - 0.95 kPa)
2.9 - 11.0 in. W.C.
(0.72 - 2.74 kPa)
Orifice size
3.4 mm dia.
#48 DMS (1.93 mm dia.)
Minimum supply pressure for purpose of input
adjustment.
5.0 - 14.0 in. W.C.
(1.2 - 3.5 kPa)
12.0 - 14.0 in. W.C.
(2.9 - 3.5 kPa)
Burner Primary Air Setting
1/8” (3.2 mm) Open
1/2” (12.7 mm) Open
Altitude
0 - 4500 ft (0 - 1372 m)
0 - 4500 ft (0 - 1372 m)
Gas Control
SIT 885 Proflame II Dynamic Start with Continuous POD
Electrical rating
120 VAC, 60 Hz, less than 2 A.
P.4.1 Fireplace Efficiency (FE)
70.08%
Replacement fan
Part # RF-305-4224 fan / blower assembly must be used
Keep burner and control compartment clean. See
Instructions accompanying the heater.
Optional fuel conversion kit : See Manual
Minimum clearances to Combustibles:
Chase sides, back & top from fireplace standoffs: 0” (0 mm).
Interior sidewall from fireplace opening: 7.25” (184.2 mm).
Mantle: 8” (203.2 mm) mantle at min 21” (533.4 mm) from top of
the fireplace opening.
Vent pipe: Sides & Bottom: 1” (25.4 mm), Top: 2” (50.8 mm).
Ceiling: 60” (1524 mm) from fireplace opening.
See Manual for additional dimensions and clearances.
See IHEAT manual for clearances with IHEAT installed.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. Electrical connections and grounding must
be in accordance with local codes, if any; if none, follow the current CAN/CSA C22.1 in Canada and ANSI/NFPA 70 in the
US. This appliance is certified for installation in a bedroom or a bed sitting room. This appliance is only for use with the gas
indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where
not prohibited by local codes. See owner’s manual for details. This appliance is not convertible with other gases, unless a
certified kit is used.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer
to the owner’s information manual provided with this appliance. For assistance or additional information consult a
qualified installer, service agency, or the gas supplier. This appliance must be properly connected to a Direct Vent
venting system in accordance with the manufacturer’s installation instructions.
WARNING: Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
WARNING: Do not operate the appliance until all sections have been assembled and installed in accordance with the
manufacturer’s instructions.
WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result
in carbon monoxide (CO) poisoning and possible death.
Only doors certified with the appliance shall be used.
For use only with barrier part # 41-BS. Follow installation instructions.
Made in Canada by:
Archgard Industries Ltd.
7116 Beatty Dr., Mission, B.C.
September 2019 303-6201-01
MANUFACTURE DATE:
2019 2020 2021
JAN
FEB MAR APR MAY
JUN JUL AUG
SEP
OCT NOV DEC