40
Installation
15.2 Reflective Glass Installation
The following steps highlight the procedure for installing Eternal Flame Reflective Ceramic Glass liner. We recommend using clean
cotton gloves when handling panels. Handle the panels with care. Inspect the panels to ensure that no damage has occurred inside the
package. Please report any damage immediately to your Authorized Archgard Dealer.
Before you begin:
•
Ensure the gas supply is turned OFF and disconnect the power supply (including backup batteries)
•
Remove barrier screen (see
Section 6.3
)
•
Remove Glass Door (see
Section 6.4
)
Step 1:
Remove the screws located in the upper corners of the
firebox near the lights.
Figure 15.2.01:
Left Side
Right Side
Step 2:
Remove the screws located in the rear corners of the
burner surround by the rear panel rest.
Left Side
Right Side
Figure 15.2.02:
Step 3:
Reinstall the burner screws with the bottom glass panel
spacers included with the Eternal Flame Reflective Ceramic Glass
set.
Left Side
Right Side
Step 4:
Make sure the upper glass retainers are within reach
before proceeding with the following steps.
Figure 15.2.03:
Figure 15.2.04:
Step 5:
Place the rear panel in the back of the firebox, behind the
tek screws on the log rest.
Left Side
Right Side
Figure 15.2.05: