
20
Installation
This fireplace is shipped with the restrictor in the open position. Follow the chart in
Section 10.2
for recommended settings based
on venting configuration. It is important to remember each installation is unique and affected by various factors including venting
configuration, altitude and climate. Therefore, after fireplace installation is complete, restrictor adjustments may be necessary. Use the
following steps to close the restrictor.
Before installation:
•
Disconnect gas and electrical supply to the fireplace (including backup batteries)
•
Remove the barrier screen (see
Section 6.3
)
•
Remove the glass door assembly (see
Section 6.4
)
10.2 Vent Restrictor Installation
Step 1:
Remove the 1/4" Tek Screw from the restrictor.
Step 2:
Slide the restrictor into the closed position.
Figure 10.2.01:
Figure 10.2.02:
Step 3:
Insert the screw that was removed in Step 1 to secure
the restrictor in the closed position.
Figure 10.2.03: