13
Installation
7.0 Electrical Connections
The
41-DVTE41LN-2
comes complete with an adjustable 6 speed fan and variable lights wired directly to the main control module.
Do not cut or remove the grounding prong from the main power supply plug.
CAUTION:
Label all wires prior to disconnection when servicing.
NOTE:
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI / NFPA 70, or the Canadian Electrical code, CSA C22.1.
Before you begin:
•
Remove the barrier screen (see
Section 6.3
)
•
Remove the glass door assembly (see
Section 6.4
)
•
Remove the wire cover and open the control board access door (See
Section 6.5
)
To supply power to the fireplace:
Step 1:
Remove the junction box from the fireplace using a 1/4"
hex driver.
Figure 7.0.01:
Step 2:
Locate the receptacle, electrical plate, and wire clamp
located in the manual bag.
Figure 7.0.02:
Step 3:
Wire according to local code and reinstall the junction box.
Step 4:
Plug the control board into the receptacle located behind
the control board.
Figure 7.0.03:
Figure 7.0.04: