This appliance is tested and certified to the following USA and Canadian gas appliance
standards.
- ANSI Z21.88b-2003 / CSA 2.33b-2003, Vented Gas Fireplace Heaters,
- CAN / CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes
Please contact Archgard Industries Ltd., if you have any questions regarding the certification of
this appliance.
APPLIANCE CERTIFICATION
INSTALLATION CODES
This appliance must be installed by a qualified gas appliance installer.
The installation must conform with the local codes or, in the absence of local codes, with the
current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1.
Electrical connections and grounding must conform with local code, or current National
Electrical code, ANSI/NFPA No. 70-1987, in the US and in Canada, the current Canadian
Electrical Code, CSA C22.1.
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 4500 ft. (1372 M) above sea level, the appliance must
be properly de-rated and installed according to local codes, in the absence of local codes, with
the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code,
CAN/CGA-B149, in Canada.
Natural Gas (NG)
Propane (LP)
Manifold Pressure
1.6 - 3.5 in. W.C. (0.4 - 0.9 kPa) 6.3 - 10.0 in. W.C. (1.6 - 2.5 kPa)
Min. Supply Pressure
for Purpose of Input
Adjustment
4.5 in. w.c. (1.2 kPa)
11.0 in. w.c. (2.8 kPa)
Orifice Size
#31 DMS (3.05 mm dia.)
#49 DMS (1.85 mm dia.)
Nominal Input Rating
27,000 - 40,000 BTU/hr
(7.9 - 11.7 kW)
30,000 - 40,000 BTU/hr
(9.1 - 11.7 kW)
ELECTRICAL RATING
120 Volts (a/c), 2.0 amps, 60 Hz 120 Volts (a/c), 2.0 amps, 60 Hz
GAS CONTROL
Milli-Valve (quick drop-out), Hi/Lo Milli-Valve (quick drop-out), Hi/Lo
Altitude
0 - 4500 ft (0 - 1372 M)
0 - 4500 ft (0 - 1372 M)
Primary Air Opening
¾ OPEN
FULLY OPEN
SPECIFICATIONS