Archgard 40-dvi40n Optima 40 - SB Скачать руководство пользователя страница 39

 
 
 
This Limited Warranty is made by ARCHGARD INDUSTRIES LTD., hereinafter referred to as “Archgard”. Archgard warrants to the 
original purchaser of an Archgard gas burning fireplace (s) that the product will be free of defects in materials and workmanship under 
normal use and service, for a “lifetime”. 

 

INCLUSIONS: “LIFETIME LIMITED WARRANTY“ 

❖  

All heat exchangers, combustion chamber, burner tubes and pans.   

❖  

Ceramic Fiber Logs and Ceramic Brick Panels against splitting or cracking. 

❖  

Ceramic Glass against thermal breakage. 

❖  

All 24 K gold trims and accessories against tarnishing. 

❖  

All trim accessories against tarnishing and paint defects. 

❖  

NOTE: Discoloration and some minor movement of certain parts are normal and are not a defect and therefore, not covered under 
warranty.   

The above will be covered “parts & labor” to the original purchaser for FIVE years and “parts” only thereafter from original date of pur-
chase. 

 

INCLUSIONS: “FIVE YEAR LIMITED WARRANTY” 

❖  

Five year limited warranty on the “FiberFlame Technology Burner System.”  Warranty will cover any defective burner and ceramic 
ember bed if defect is deemed as original by the manufacturer. 

The above will be covered “parts & labor” to the original purchaser for TWO years and “parts” only thereafter from original date of pur-
chase. 

 

INCLUSIONS: “ONE YEAR LIMITED WARRANTY”  

❖  

Blowers, fans and fan motors, wiring, rheostats and thermodiscs. 

❖  

Rocker switches, spill switches and wiring to them.  

❖  

Gas control valves, pilot assemblies including thermopiles, thermocouples, electrodes, and igniters. 

The above will be covered “parts & labor”  to the original purchaser for ONE year from date of purchase.  

 

EXCLUSIONS: 

❖  

Archgard does not offer wall mounted thermostats, programmable thermostats (wiring for hook-up of said product), handheld remote 
controls, fireplace mantel (s), trims or tiles.  

❖  

Ember material. 

❖  

Tempered Glass is under warranty for ONE year to the original purchaser from date of purchase. 

❖  

Travel time or mileage to original purchasers residence. Archgard suggests that you pre-arrange travel expenses with your Authorized 
Archgard Dealer. 

 

 

WHAT TO DO IN THE EVENT OF A PROBLEM: 

❖  

Thoroughly read your manual. 

❖  

If you cannot solve the problem, contact your Archgard Dealer or representative.  

❖  

When calling for help please have the following information:  

            

Model of your Fireplace 

Serial Number 

Place of Purchase                            

            Date of Purchase 

Problem Description 

❖  

NOTE: Warranty may be void if work is carried out by an unqualified person (s). Only original Archgard parts may be used. Please 
consult your Archgard dealer or representative if in doubt about a replacement part (s). 

 

OBTAINING WARRANTY SERVICE: 
To obtain warranty service, the original purchaser shall return the defective part (s) to the original authorized Archgard selling dealer 
transportation prepaid, along with the serial number of the appliance and proof of purchase. Any defective part, in our  
judgment, will be repaired or replaced at Archgard’s discretion. The dealer must obtain approval from Archgard before any  
repairs are made.  

 

WARRANTY LIMITATION: 
THIS LIMITED WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED AS TO QUALITY, 
MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE. 

 

The appliance is only warranted for the use as intended by the installation and operating instruction and local building codes. The war-
ranty will not cover damage due to accident, misuse, abuse, alteration, improper installation or “Acts Of God”.  
This limited warranty is void unless the appliance is installed by a qualified installer, in accordance with the instructions  
furnished with the appliance. Some Provinces or States do not allow limitations on how long an implied warranty lasts, so the above limi-
tation may not apply to the original purchaser. Any damage resulting from defects in this product, is limited to the  
replacement of the defective part (s) and does not include incidental and consequential exposures sustained in connection with the prod-
uct. This includes facing (s),   mantle (s), cabinet (s), tile (s) or any other finishes resulting from removal of any gas appliance. This war-
ranty is limited to residential use only and gives the consumer specific rights. These rights may vary from State to State or Province to 
Province. 

 

ARCHGARD

ARCHGARD

 

 

LIMITED WARRANTY

LIMITED WARRANTY

 

 

Содержание 40-dvi40n Optima 40 - SB

Страница 1: ...ions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Installer Please leave this m...

Страница 2: ...tate or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and sig...

Страница 3: ...control Adjustable Flame The flame aesthetics and heat output can be adjusted to suit the owner s liking and heating needs Solid Construction The 40 DVI40N is mainly constructed of 16 and 18 gauge ga...

Страница 4: ...ng Instructions on Rating Plate 23 Glass Door Removal If Your Glass Breaks 24 Optional Bay Door Installation Instructions 25 Troubleshooting Guide 26 Maintenance Cleaning the Appliance 28 Servicing Un...

Страница 5: ...vice person More frequent cleaning may be required due to excessive lint from carpeting bedding materials et cetera It is imperative that the control compartments burners and circulating air passagewa...

Страница 6: ...No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 HIGH ALTITUDE INSTALLATION When installing this appliance beyond 4500 ft 1372 M above sea level the appliance must be...

Страница 7: ...s of the fireplace in which the gas fireplace insert is to be installed is prohibited If the factory built fireplace has no gas access hole s provided an access hole of 1 37 5 mm or less may be drille...

Страница 8: ...replace surround to a sidewall or mantle support See APPLIANCE DIMENSIONS for surround sizes SIDE VIEW Note With bay window attached clearances remain the same 6 152 mm Minimum Height From Bottom of A...

Страница 9: ...the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 5 kPa Failure to...

Страница 10: ...ONS The Optima 40 SB comes complete with a temperature activated fan and rheostat installed and wired to a three prong grounding plug for your protection against shock hazard and should be plugged in...

Страница 11: ...ht as possible avoiding unnecessary bending but at all times keep a minimum of 3 76 mm inside bend radius The Air Intake Flex Liner must be connected to the inlet air collars of the termination cap an...

Страница 12: ...ovided 6 Seal and attach the liner marked Exhaust to the vent terminal pipe marked Exhaust with the collar clamp provided 7 Seal and attach the end of the flex marked Air Intake to the collar marked A...

Страница 13: ...ON Only trim kit s supplied by the manufacturer may be used in the installation of this appliance 1 Using the trim clips provided join the left side trim which has notch cut for rocker switch to the t...

Страница 14: ...y wall switch or wall thermostat and will not extend warranty to them OPTIONAL WALL SWITCH OR THERMOSTAT Thermostat wall switch wire table Recommended Maximum Lead Length for two wires Wire Size Max L...

Страница 15: ...ed in side the package Please report any damage immediately to your Authorized Archgard Dealer Gas and vent connection must be made before installing the embers and logs on the pan burner NOTE Imprope...

Страница 16: ...ce it on the left side of burner aligning the pins on the burner with holes in the log as shown Step 1 Locate log 1 and place it on the right side of burner aligning the pins on the burner with holes...

Страница 17: ...ued Step 3 Locate log 3 and place it on the left side of burner aligning the pins on the burner with holes in the log as shown Step 4 Locate log 4 and place it on the burner aligning the pins on the b...

Страница 18: ...Optima 40 SB 18 LOG PLACEMENT Continued Step 5 Locate log 5 and place it on the burner as shown Step 6 Locate log 6 and place it as shown...

Страница 19: ...d Step 7 Locate Embers Part 310 0019 and place as shown IMPORTANT Embers should not be placed over the burner ports Do not block off burner ports or air passages under the left and right logs or the t...

Страница 20: ...s please contact the Authorized Archgard Dealer where you purchased your appliance to order replacements CERAMIC BRICK PANELS Step 9 Locate Grate and place it as shown Rear Brick Panel Placement as Sh...

Страница 21: ...Optima 40 SB 21 BRICK PLACEMENT Continued Right Brick Panel Placement as Shown...

Страница 22: ...B 22 Left Brick Panel Placement as Shown NOTE Installing the panels in any other position other than shown will result in flame im pingement causing sooting of the logs brick liner and ceramic glass v...

Страница 23: ...working order This will include 1 Perform leak tests of supply line gas control valve supply line from gas control valve and pilot assembly 2 Clocking the appliance to ensure the correct firing rate...

Страница 24: ...ualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water WARNING If you do not follow these instructions exactl...

Страница 25: ...ions exactly a fire of explosion may result causing property damage personal injury or loss of life 1 STOP Read the safety information above on this label 2 Set the remote switch to OFF Set the thermo...

Страница 26: ...lacing the Glass Door The reverse procedure of Removing the Glass Door IF YOUR GLASS BREAKS WARNING Do not substitute glass components with other material types Do not abuse the glass doors such as st...

Страница 27: ...g instructions 1 Remove the upper grilles by pulling the assembly forward 2 Remove the lower grilles by removing the four hex head mounting screws that secure the brass hinges to the unit 3 Discard th...

Страница 28: ...ive Pilot will not remain on after being lit 1 Press the control knob all the way in at the pilot indicator 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the p...

Страница 29: ...ck wire connections Expansion from heat affects a loose con nection Sooty deposits on the glass door 1 If the flame is yellow and lazy check for lint etc around primary air shutter Increase primary ai...

Страница 30: ...pors and liquids Visually check the height and color of the burner and pilot flames Every 2 to 3 months Remove the glass door and clean the inside of the glass with a soft non abrasive cloth and water...

Страница 31: ...by Archgard for suitability Note the Shutter is set at the factory and normally only requires resetting at higher altitudes Caution Wear gloves when adjusting the primary air with the appliance hot 1...

Страница 32: ...al for reassembly 3 Remove the logs See LOG PLACEMENT for instructions 4 Unscrew the two mounting screws that are located at the back rear of the pan burner 5 Carefully remove the pan burner by slidin...

Страница 33: ...G INLET AND OUTLET GAS PRESSURE CHECKING AND ADJUSTING PILOT Fig 1 CONVERTIBLE PILOT ORIFICE The pilot assembly is convertible to the type of gas being used simply unscrew the body by using a 7 16 11...

Страница 34: ...its equivalent 1 Remove the glass door Follow GLASS DOOR REMOVAL instructions within this manual 2 Remove the log set Follow LOG PLACEMENT instructions within this manual 3 Loosen the adjustment wing...

Страница 35: ...Orifice Main Burner Orifice Drill to 34 DMS 2 76 mm for Natural Gas Drill to 51 for LP Propane Gas 1 EA E 620 0004 Aluminum Pilot Box 1 EA F 314 0127 Gasket Ceramic Paper 1 EA G 314 0127 Gasket Ceram...

Страница 36: ...400 2 Premium Log 2 1 EA 310 6400 3 Premium Log 3 1 EA 310 6400 4 Premium Log 4 1 EA 310 6400 5 Premium Log 5 1 EA 310 6400 6 Premium Log 6 1 EA 310 6400 Complete 6 piece Logset replacement 1 EA 840 0...

Страница 37: ...9 On Off Rocker Switch 1 EA Fan Components 305 0012 Power Cord 8 2 43 M 1 EA 305 0013 Fan Speed Control Rheostat 1 EA 305 0021 Fan Thermodisc fan sensor 1100 F 430 Celsius 1 EA RF 305 0024 Fan Fan wit...

Страница 38: ...BAYG Optional Gold Bay Window Strips Full Set Includes top bottom trim pieces 1 EA Optional Surround Trims 40 TKSB Black Trim for SKBAB SKCAB surround 1 SET 40 TKLB Black Trim for SKLB surround 1 SET...

Страница 39: ...r Authorized Archgard Dealer WHAT TO DO IN THE EVENT OF A PROBLEM Thoroughly read your manual If you cannot solve the problem contact your Archgard Dealer or representative When calling for help pleas...

Страница 40: ...icking cracking or pinging sound when my fireplace is running and after it is turned off A The different gauges of steel used to manufacture your fireplace will expand and contract at different rates...

Страница 41: ...Optima 40 SB 41 NOTES...

Страница 42: ......

Страница 43: ...CLOSED CUT ALONG LINE CUT ALONG LINE CUT ALONG LINE Model 40 DVI40N Serial Date Installed Name Address City State Prov Phone ______ Dealer s Name Address City State Prov Phone ______ Installer s Name...

Страница 44: ......

Страница 45: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...