Installation
11.3 Ventilation Framing
5.08cm 2.00in
133.84cm 52.691in
25.40cm
10.00in
107.64cm 42.38in
120.34cm 47.3785in
25.40cm
10.00in
22.86cm
9.00in
Ventilation framing dimensions are based on Duravent venting components. If other third party venting components are used, refer
to the installation instructions from the third party manufacturer for installation information. The following critical dimensions must be
maintained regardless of venting manufacturer:
Item
Critical Dimensions
Distance from ceiling
to horizontal pipe
2" (5.08 cm)
Thimble framing
dimensions
9" (22.86 cm) W x
10" (25.4 cm) H
Ceiling height and the height to the bottom of the thimble shown are based on a minimum vent run. These values may vary depending
on the requirements of each installation.
Figure 11.3.01
I
MPORTANT
WARNING
Vent cap location must be in compliance with guidelines in
Section 10.4
of this manual.
DO NOT RECESS VENT CAP INTO WALL OR SIDING.