15
Installation
NOTE
This product must be installed by a qualified installer. The installer should follow the procedure best suited for each specific
installation.
1.
Frame an opening for the fireplace, allowing for vent installation and type of installation (corner or flat wall application).
2.
Attach nailing flanges to fireplace.
3.
Insert fireplace into framing.
4.
Install hearth (if applicable).
5.
Complete electrical hook-up.
6.
Complete gas line installation.
7.
Complete venting installation.
8.
Secure fireplace to framing with nailing flanges. Verify all clearances.
9.
Install facing material (refer to
Section 12
for clearance information), mantel or cabinetry.
10.
Install the panel set. Many options are available from your local Archgard dealer.
11.
Install the logs, glass door assembly, and barrier screen.
12.
Verify proper operation of fireplace and all components.
PLACEMENT CLEARANCE REQUIREMENTS
•
This fireplace must be installed on a level surface capable of supporting the fireplace and venting
•
Fireplace must be placed directly on wood or non-combustible surface (not linoleum or carpet) extending entire depth and width of
fireplace
•
Facing material must be all non-combustible (see
Section 12
for detailed clearance information)
•
Due to high surface temperatures, fireplace should be located out of traffic and away from furniture and draperies
•
This fireplace may be installed in a bedroom (see local codes)
•
Please be aware of the large amount of heat this fireplace will produce when determining a location
9.1 Installation Overview
9.0 Prepare The Fireplace
9.2 Nailing Flange Installation
CAUTION
Always install nailing flanges regardless of installation variances
.
1:50
SIZE DWG. NO.
A
REV.
SHEET 9 OF 10
WEIGHT:
41-DVT Framing
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
CHECKED
DRAWN
DATE
NAME
8/24/2017
PROPRIETARY AND CONFIDENTIAL
U:\R&D\Prototype CADD\41-DVT Prototype\41-DVT Framing
Thursday, August 24, 2017 3:07:49 PM
SCALE
Wall Board Thickness
(Nailing Flange Setting)
3/4"
5/8"
1/2"
3/8"
Side Nailing Flanges
Attach the side nailing flanges to the
sides of the fireplace using the (4) 1/4"
tek screws included in the manual bag
(two per side).
Depending on the facing material, the
nailing flanges can be adjusted forward
or backwards (see
Figure 9.2.01
)
Figure 9.2.01:
Side Nailing
Flange
O
3/4"
O
5/8"
O
1/2"
O
3/8"
Содержание 37-DVTE30LN-1
Страница 76: ......