9
Installation
6.4 Accessing the Control Board
The control board is located on the right side of the fireplace, behind
the fireplace surround (see
Section 6.1
). To access the control
board:
1.
Ensure the fireplace is off and cool.
2.
Disconnect power supply.
3.
Remove Fireplace Surround.
Figure 6.4.01:
7.0 Electrical Connections
The
36-DVIE40LN-1
comes complete with an adjustable 6 speed fan and variable lights wired directly to the main control module.
Do not cut or remove the grounding prong from the main power supply plug.
CAUTION:
Label all wires prior to disconnection when servicing.
NOTE:
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI / NFPA 70, or the Canadian Electrical code, CSA C22.1.
6.5 Accessing the Gas Valve
The valve is located on the left side of the fireplace, behind the
fireplace surround (see
Section 6.1
). To access the valve:
1.
Ensure the fireplace is off and cool.
2.
Disconnect power supply.
3.
Remove Fireplace Surround.
Figure 6.4.01:
SW1 (Sync Button)
Battery Backup