4.0 Rating Plate
9-
1/4”
12”
SHEET
SHEET
SHEET
SHEET
March 23, 2017
36-DVI_ RATING PLATE
Material - Class III
Black Letters on silver Mylar background
MODEL:
36-DVI40LN-1
(SIT 885 Proflame)
DO NOT REMOVE THIS LABEL
LISTED VENTED GAS FIREPLACE HEATER and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES. Tested to: ANSI Z21.88-2014 / CSA
2.33-2014 and CAN/CGA-2.17-M91. This vented gas fireplace heater is not for use with air filters. Certified for use in both CANADA and USA.
VENTED GAS FIREPLACE HEATER-NOT FOR USE WITH SOLID FUEL.
NG
LPG
Input rating
22,000 - 40,000 BTU/hr
(6.45 - 11.72 kW)
20,000 - 40,000 BTU/hr
(5.86 - 11.72 kW)
Manifold Pressure
1.1 - 3.8 in. W.C. (0.27 - 0.95 kPa)
2.9 - 11.0 in. W.C. (0.72 - 2.74 kPa)
Orifice size
3.4 mm dia.
#48 DMS (1.93 mm dia.)
Supply pressure (Min - Max)
5.0 - 14.0 in. W.C. (1.2 - 3.5 kPa)
12.0 - 14.0 in. W.C. (2.9 - 3.5 kPa)
Burner Primary Air Setting
1/16” (1.6mm) Open
100% Open
Altitude
0 - 4500 ft (0 - 1372 m)
0 - 4500 ft (0 - 1372 m)
Electrical rating
120 VAC, 60 Hz less than 2 A.
Replacement fan
RF-305-0024
Keep burner and control compartment clean. See Instructions
accompanying the heater.
Optional fuel conversion kit : See Manual
Minimum opening Dimensions:
37.875”(962 mm)W x 24”(610 mm)H x 18.5”(469.9 mm)D
Minimum Chimney Flue Size:4” (100 mm) x 7” (176 mm)
Minimum clearances to Combustibles:
Sides from glass door frame: 8” (203.2 mm)
Mantle: max 12” (305 mm) at min 20” (508 mm)
from top of appliance door
See Manual for additional dimensions and clearances
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or
Natural Gas and Propane Installation Codes, CSA B149.1. Electrical connections and grounding must be in accordance with local codes, if any;
if none, follow the current CAN/CSA C22.1 in Canada and ANSI/NFPA 70 in the US. This appliance is certified for installation in a bedroom or
a bed sitting room. This appliance is only for use with the gas indicated on the rating plate and may be installed in an aftermarket, permanently
located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible
with other gases, unless a certified kit is used.
WARNING:
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to the owner’s
information manual provided with this appliance. For assistance or additional information consult a qualified installer, service
agency, or the gas supplier. This appliance must be properly connected to a Direct Vent venting system in accordance with the
manufacturer’s installation instructions.
WARNING:
Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically approved with this
appliance may result in property damage or personal injury.
WARNING:
Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer’s
instructions.
WARNING:
Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon
monoxide (CO) poisoning and possible death.
ONLY DOORS CERTIFIED WITH THE APPLIANCE SHALL BE USED.
For use only with barrier part # 36-BS. Follow installation instructions.
Made in Canada by:
Archgard Industries Ltd.
7116 Beatty Dr., Mission, B.C.
March 2017 303-6400-01
NE PAS ENLEVER CETTE ÉTIQUETTE
RADIATEUR VENTILE, CIRCULATEUR DU TYPE VENTILATEUR. Testée selon les normes : ANSI Z21.88-2014 / CSA 2.33-2014 et CAN/CGA-
2.17-M91. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation. Certifié pour utilisation dans le Canada et les ÉTATS-UNIS.
FOYER AU GAZ À ÉVACUATION. NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
NG
LPG
Entrée assignée
22 000 - 40 000 BTU/hr
(6,45 - 11,72 kW)
20 000 - 40 000 BTU/hr
(5,86 - 11,72 kW)
Pression d’admission
1,1 - 3,8 po c.e (0,27 - 0,95 kPa)
2,9 - 11,0 in. c.e (0,72 - 2,74 kPa)
Dimension de l’orifice
3.4 mm dia.
#48 DMS (1.93 mm dia.)
Pression d’alimentation (min - max)
5,0 - 14,0 po c.e (1,2 - 3,5 kPa)
12,0 - 14,0 po c.e (2,9 - 3,5 kPa)
Réglage de l’air primaire du brûleur
1/16 po (6 mm) Ouvrir
100% Ouvrir
Elevation
0 - 4500 pieds (0 - 1372 M)
0 - 4500 pieds (0 - 1372 M)
Tension électrique
120 V, 60 Hz Moins que 2 A.
Ventilateur de remplacement
RF-305-0024
Maintenir propres le brûleur et le compartiment de com-
mande. Voir les instructions relatives à l’installation et au
fonctionnement qui accompagnent le radiateur.
Trousse de conversion de combustible optionnel : Voir le
manuel
Minimales dimensions d’ouverture:
37.875 po (962 mm)W x 24 po (610 mm)H x 18.5 po(469.9 mm)D
Cheminée minimale de fumée:
4” (100 mm) x 7” (176 mm)
Minimales entre l’appareil et les combustibles:
Côtes: 8 ” (203.2 mm)
Manteau: max 12” (305 mm) à min 20” (508 mm) du haut de la porte
de l’appareil.Voir le manuel pour les dimensions et les dégagements
supplémentaires
Il faut que cet appareil soit installé selon les codes locaux, s’il y en a; sinon, suivre le CAN/CGA-B149.1 actuel au Canada et ANSI Z223.1 aux
É.-U. Il faut que le raccordement électrique et la mise à la masse soient en conformité avec les codes locaux, s’il y en a; sinon, suivre le CAN/
CSA C22.1 actuel au Canada et ANSI/NFPA 70 aux É.-U. Cet appareil est certifié pour l’installation dans une chambre à coucher ou une pièce
qui sert de chambre. Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être
installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice
de l’utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d’’autres gaz sauf si une trousse de conversion certifiée
est fournie.
AVERTISSEMENT:
Une installation, un réglage, une modification, une réparation ou un entretien mal effectué peut causer des dommages
atériels ou des blessures. Voir la notice de l’utilisateur qui accompgne l’appareil. Pour de l’aide ou des renseignements
supplémentaires, consultez un installateur, un technicien agréé ou le fournisseur de gaz. Cet appareil doit être
corectement raccordé à un système d’évacuation direct, conformément aux instructions du fabricant.
AVERTISSEMENT :
Risque de dommages ou de blessures si l’appareil n’est pas installé selon les instructions du fabricant ou si des pièces
autres que celles spécifiquement approuvées avec cet appareil sont utilisées.
AVERTISSEMENT :
Ne pas utiliser l’appareil tant que toutes les sections n’ont pas été assemblées et installées selon les instructions du
fabricant.
AVERTISSEMENT :
Si cet appareil fonctionne sans être raccordé à un système d’évacuation correctement installé et entretenu, ou si le
système d’évacuation es modifié, il peut en résulter un empoisonnement au monoxyde de carbone et la mort.
SEULES DES PORTES CERTIFIÉES POUR CET APPAREIL DOIVENT ÊTRE UTILISÉES.
Utiliser uniquement avec l’écran no 36-BS. Suivre les instructions d’installation.
Fabrique au Canada par:
Archgard Industries Ltd.
7116 Beatty Dr., Mission, B.C.
mars 2017 303-6400F-01
MODÈLE:
36-DVI40LN-1
(SIT 885 Proflame)
MANUFACTURE DATE: 2016 2017 2018 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
date de fabrication:
2016 2017 2018 jan
fév mar avr mai jun
jul août sep oct nov dec
SAMPLE