20.14 Replacing the Fan
Before you begin:
•
Ensure the fireplace is off and cool before servicing
•
Disconnect power supply (including back-up battery power) to the fireplace
•
Turn off gas supply
•
Remove the fireplace surround
•
Remove barrier screen - See
Section 14.0
•
Remove door assembly - See
Section 15.0
•
Remove burner media - See
Section 18.0
•
Remove the burner - See
Section 20.12
CAUTION:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing. This appliance, when installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code,
CSA C22.1
.
Step 1:
Remove the (2) Tek screws securing the rear firebox
panel.
Figure 20.14.01:
Step 2:
Remove the rear firebox panel.
Figure 20.14.02:
Step 3:
Remove the (5) Tek screws securing the burner support
bracket.
Figure 20.14.03:
Step 4:
Remove the burner support bracket.
Figure 20.14.04: