54
Maintenance
20.12 Removing the Burner
Before you begin:
•
Ensure the fireplace is off and cool before servicing
•
Disconnect power supply (including back-up battery power) to the fireplace
•
Turn off gas supply
•
Remove the fireplace surround. See
Section 16.0
•
Remove barrier screen. See
Section 14.0
•
Remove door assembly. See
Section 15.0
•
Remove burner media. See
Section 18.0
•
Remove panel set (if applicable). See
Section 17.0
Step 1:
Remove the (5) Tek screws securing the ember strip at
the front of the burner.
Step 2:
Remove the (9) Tek screws securing the burner.
Figure 20.12.02:
Figure 20.12.01:
Step 3:
Carefully lift the burner up and away from the appliance.
Figure 20.12.03:
Installation is the reverse of removal.
Test pilot and burner operation according to
Section 20.4 and Section 20.5.
Содержание 36-DVIE40LN-1
Страница 68: ...April 11 2017...