53
Maintenance
20.11 Removing the Intake Restrictor
Before you begin:
•
Ensure the fireplace is off and cool before servicing
•
Disconnect power supply (including back-up battery power) to the fireplace
•
Turn off gas supply
•
Remove the fireplace surround. See
Section 16.0
•
Remove barrier screen. See
Section 14.0
•
Remove door assembly. See
Section 15.0
•
Remove burner media. See
Section 18.0
•
Remove panel set (if applicable). See
Section 17.0
•
Remove the burner. See
Section 20.12
Step 1:
Remove the (2) Tek screws securing the rear firebox
panel.
Figure 20.11.01:
Step 2:
Remove the rear firebox panel.
Figure 20.11.02:
Step 3:
Remove the (5) Tek screws securing the burner support
bracket.
Figure 20.11.03:
Step 4:
Remove the burner support bracket.
Figure 20.11.04:
Step 5:
Remove the (4) Tek screws securing the restrictor plate
and remove the plate.
Step 6:
Reinstall the (4) Tek screws that were removed in Step 5.
Step 7:
Reinstall the burner support bracket and rear firebox
panel.
Step 8:
Reinstall the panel set, burner media, door assembly,
barrier screen, and fireplace surround.
Step 9:
Resupply gas and power. Verify proper operation.
Figure 20.11.05:
Содержание 36-DVIE40LN-1
Страница 68: ...April 11 2017...