15
Installation
10.0 Clearances to Combustibles
WARNING:
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this
appliance may result in property damage or personal injury or loss of life.
CAUTION:
This appliance is designed for use in any masonry or factory-built, wood-burning fireplace. It cannot be enclosed by
combustible material and used as a factory built gas fireplace (zero clearance fireplace).
Figure 10.1.01
10.1 Mantel Clearances
10.2 Minimum Sidewall Clearances
Figure 10.2.01
Maintain a minimum of 8" (203.2 mm) clearance
from the side of the door to sidewalls or mantel
supports.
Mantel clearances are measured from
the top of the appliance door. Ensure
combustible material is not placed
within the area shown.
8"
(203 mm)
8"
(203 mm)
16"
(406.4 mm)
18"
(457.2 mm)
20"
(508 mm)
14"
(355.6 mm)
12"
(304.8 mm)
Ceiling clearance:
48" (1219.2 mm)
from the top of the appliance door.
22"
(558.8 mm)
22.79"
(578.9 mm)