8
Installation
6. 0 Ap p l i a n c e Ov e r v i e w
6. 1 Ap p l i a n c e Ov e r v i e w
Surround
Left Side
Right Side
The Proflame II control board is located on the
right side* of the fireplace behind the surround.
The valve is located on the left side* of the
fireplace behind the surround.
The fan is located on the inside of the rear
fireplace shell and can be accessed from
the rear of the fireplace or from the front by
removing the burner.
No t e :
This manual uses images of an unpainted
fireplace for the purposes of illustration.
*Left and right side references in this manual
correspond with the sides identified in
Fi g u r e
6. 1. 01
.
6. 2 Le v e l i n g t h e Ap p l i a n c e
The
36-DVIE40LN-1
is equipped with front and rear leveling bolts.
The fireplace has the ability to independently level left/right and
front/back.
Leveling is done from the bottom of the unit
Fi g u r e 6. 1. 01:
Fi g u r e 6. 2. 01:
Fr o n t Bo l t s
Re a r Bo l t s
Rating Plate
6.3 Configuring the Controls
The controls on the
36-DVIE40LN-1
may be relocated to allow for
installation in most larger masonry fireplace openings. To relocate
the controls, remove the (3) tek screws securing each control panel
and reattach in the configuration of your choosing.
Each fireplace ships in the "Controls In" position.
No t e :
Be sure to check the installation opening dimensions to
choose the appropriate trim for your install. The deep trim is
required when converting to a "Controls Out" installation.
Fi g u r e 6. 3. 01:
TOP VIEW
C ONTROLS IN
TOP VIEW
C ONTROLS OU T