6
General Information
4. 0 Ra t i n g Pl a t e
MODEL:
36-DVIE40LN-1
(SIT 885 Proflame)
DO NOT REMOVE THIS LABEL
LISTED VENTED GAS FIREPLACE HEATER and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES. Tested to: ANSI
Z21.88-2019 / CSA 2.33-2019 and CAN/CGA-2.17-M91 (R2014), CSA P.4.1-2015 - Testing Method for Measuring Annual Fireplace
Efficiency,CSA C22.2 No.3 - M1998(R.2014) - Electrical Features of Fuel-Burning Equipment. This vented gas fireplace heater is
not for use with air filters. Certified for use in both CANADA and USA.
VENTED GAS FIREPLACE HEATER-NOT FOR USE WITH SOLID FUEL.
NG
LPG
Input rating
22,000 - 40,000 BTU/hr
(6.45 - 11.72 kW)
20,000 - 40,000 BTU/hr
(5.86 - 11.72 kW)
Manifold Pressure
1.1 - 3.8 in. W.C. (0.27 - 0.95
kPa)
2.9 - 11.0 in. W.C. (0.72 - 2.74
kPa)
Orifice size
3.4 mm dia.
#48 DMS (1.93 mm dia.)
Supply pressure (Min - Max)
5.0 - 14.0 in. W.C. (1.2 - 3.5
kPa)
12.0 - 14.0 in. W.C. (2.9 - 3.5
kPa)
Burner Primary Air Setting
1/16” (1.6mm) Open
100% Open
Altitude
0 - 4500 ft (0 - 1372 m)
0 - 4500 ft (0 - 1372 m)
Gas Control
SIT 885 Proflame II Dynamic Start with Continuous POD
Electrical rating
120 VAC, 60 Hz less than 2 A.
P.4.1 Fireplace Efficiency (FE)
76.95%
Replacement fan
RF-305-0024
Keep burner and control compartment clean. See
Instructions accompanying the heater.
Optional fuel conversion kit : See Manual
Minimum opening Dimensions:
37.875”(962 mm)W x 24”(610 mm)H x 18.5”(469.9 mm)D
Minimum Chimney Flue Size:4” (100 mm) x 7” (176 mm)
Minimum clearances to Combustibles:
Sides from glass door frame: 8” (203.2 mm)
Mantle: max 12” (305 mm) at min 20” (508 mm)
from top of appliance door
See Manual for additional dimensions and clearances
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. Electrical connections and grounding must
be in accordance with local codes, if any; if none, follow the current CAN/CSA C22.1 in Canada and ANSI/NFPA 70 in the
US. This appliance is certified for installation in a bedroom or a bed sitting room. This appliance is only for use with the gas
indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where
not prohibited by local codes. See owner’s manual for details. This appliance is not convertible with other gases, unless a
certified kit is used.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer
to the owner’s information manual provided with this appliance. For assistance or additional information consult a
qualified installer, service agency, or the gas supplier. This appliance must be properly connected to a Direct Vent
venting system in accordance with the manufacturer’s installation instructions.
WARNING: Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
WARNING: Do not operate the appliance until all sections have been assembled and installed in accordance with the
manufacturer’s instructions.
WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result
in carbon monoxide (CO) poisoning and possible death.
ONLY DOORS CERTIFIED WITH THE APPLIANCE SHALL BE USED.
For use only with barrier part # 36-BS. Follow installation instructions.
Made in Canada by:
Archgard Industries Ltd.
7116 Beatty Dr., Mission, B.C.
November 2021 303-6400-04
MANUFACTURE DATE:
SAMPLE