Maintenance
20. 7 Re p l a c i n g Fu s e
1.
Ensure the fireplace is off and cool before servicing.
2.
Disconnect power supply (including back-up battery
power) to the fireplace.
3.
Remove the fireplace surround.
4.
Remove the fuse holder from the control board
located on the right side of the fireplace.
5.
Replace the fuse with one which has the same
specifications using the existing fuse holder.
6.
Replace surround and resupply power.
7.
Light the fireplace to verify proper operation.
Fu s e t y p e :
T3.15AL250V.
Ar c h g a r d Pa r t Nu m b e r :
RP-305-2080
Fi g u r e 20. 7 . 01:
20. 8 Re p l a c i n g Li g h t Bu l b s
C a u t i o n :
Always handle bulbs with cotton gloves as finger prints
may reduce the life of the bulb. We recommend replacing both
bulbs at the same time.
1.
Ensure the fireplace is off and cool before servicing.
2.
Disconnect power supply (including back-up battery power)
to the fireplace.
3.
Turn off gas supply.
4.
Remove the fireplace surround (optional).
5.
Remove the barrier screen. See
Se c t i o n 14. 0
.
6.
Remove the door assembly. See
Se c t i o n 15. 0
.
7.
Pull the expired bulb to remove.
8.
Replace with a bulb of the same specifications.
9.
Ensure burner media has not been disturbed.
10.
Replace door, barrier screen, and surround.
11.
Resupply gas and power.
12.
Light the fireplace to verify proper operation. See
Se c t i o n
19 . 5
for information on using the remote to control the
lights.
Fi g u r e 20. 8 . 01:
Fi g u r e 20. 8 . 02:
Bulb specification:
120V / 20W
G6.35
HALOGEN