52
Operation
Automatic Safety Shut-O
This system will execute an automatic turn OFF command after a 24hr continuous main burner flame ignition. This allows the system to
verify correct safety functions.
Di a g n o s t i c In d i c a t i o n In f o r m a t i o n :
LOW BATTERY CONDITION (Less than 4V):
Re m o t e C o n t r o l
- Battery Icon will appear on LCD remote control display. Replace batteries.
Ba t t e r y Ba c k -u p
- Red LED indicator will enter a (1) blink sequence. IFC Module will emit a double-beep when it receives an ON/OFF command from
the hand held remote. Replace batteries.
Pi l o t Fl a m e Er r o r C o n d i t i o n :
- Red LED Indicator will commence a (2) blink sequence. Contact your dealer if this occurs.
Sy s t e m Lo c k Ou t C o n d i t i o n :
- Red LED Indicator will commence a (3) blink sequence. Make sure your gas is turned on.
- Make sure pilot sensor is not shorted out.
- Follow reset information above if the module goes into a Lock Out state.
K e y Lo c k
This function will lock the keys to avoid unsupervised operation.
•
To activate this function, press the MODE and UP Keys at the same time
•
To deactivate this function, press the MODE and UP Keys at the same time
Low Battery Power Detection (Less than 4V)
Re m o t e
The life span of the remote control batteries depend on various factors:
•
Quality of the batteries used
•
The number of ignitions of the appliance
•
The number of changes to the room temperature set point, etc
When the Remote batteries are low, a Battery Icon will appear on the LCD display
of the Remote before all battery power is lost. When the batteries are replaced this
Icon will disappear.
BACKUP BATTERY PACK (used when 120V home electrical power is interrupted):
•
Red LED indicator on the IFC Module will enter a (1) blink sequence
•
Backup batteries lifespan depends on various factors including battery quality, number of ignitions, changes to room thermostat
set point, etc. When batteries are low, a double beep will be emitted from the IFC control module when it receives an ON/OFF
command from the remote control
•
This is an alert for a low battery condition of the backup batteries and after this double-beep warning, no commands will be
accepted until batteries are replaced
•
When batteries are replaced a beep will be emitted from IFC control module as soon as powered
Fi g u r e 19 . 5. 13:
Fi g u r e 19 . 5. 14: