51
Operation
Room Thermostat (Remote Operation)
The Remote Control can operate as a room thermostat. The thermostat can
be set to a desired temperature to control the comfort level in a room.
To activate this function:
•
Press the Thermostat Key. The LCD display on the remote will change
to show that the room thermostat is “ON” and the set temperature is
now active
•
To adjust the temperature, press the Up/Down Arrow Keys until the
desired temperature is displayed
SMART Thermostat (Remote Operation)
The Smart Thermostat function adjusts the flame height automatically in accordance to the difference between the set point and the
actual room temperature. As the room temperature approaches the set point, the Smart Function will modulate the flame down.
To activate this function:
•
Press the Thermostat Key until the word “SMART” appears to the right of the temperature bulb graphic
•
To adjust the set temperature, press the Up/Down Arrow Keys until the desired set temperature is displayed
NOTE
When the fireplace is started in Smart Thermostat mode:
1.
The fan will automatically activate 5min after ignition and shut down 12min after fire is turned off.
2.
Manual Flame height adjustment is disabled.
Fi g u r e 19 . 5. 10:
Fi g u r e 19 . 5. 11:
Continuous Pilot on Demand / Intermittent Pilot (CPI/IPI) Selection
With the system in “OFF” position press the Mode Key to index to the
CPI mode icon.
Pressing the UP Arrow Key will activate the Continuous Pilot on Demand
Ignition mode (CPI). Pressing the Down Arrow Key will return to IPI. A
single “beep” will confirm the reception of the command.
Fi g u r e 19 . 5. 12:
C PI v s IPI:
Continuous Pilot on Demand Ignition (CPI)
: In this mode the pilot runs continuously even when the main burner is off. The
Continuous Pilot on Demand Ignition operates on a seven day cycle. If the main burner is not turned on for seven continuous days, the
pilot will turn itself off. When the main burner is lit again the cycle repeats. The pilot will remain lit for seven days, even after the main
burner is turned off. If the main burner is lit during a seven day timing cycle, the seven day timer will reset.
Intermittent Pilot Ignition (IPI)
: A fuel saving mode in which the pilot is only used when the main burner is on.
This appliance is shipped in IPI mode. IPI mode is often the preferred method, however, there are some situations where it may be
preferable to switch the fireplace into CPI mode. For example, in colder climates the glass door or the front of the fireplace could
become very cold to the touch. Dynamic Start Advantage will solve most problems experienced by older IPI operated fireplaces.