Installation
13. 3 Mi n / Ma x Ve n t Ru n
Instructions for installing venting and terminations (see list for approved venting and terminations).
Install the termination cap being sure to provide sufficient space (around and on top) so you do not impede the flow of air,
b o t h i n t o a n d o u t o f t h e c a p . Th i s c a p i s o n l y t o b e u s e d f o r n o n c o m b u s t i b l e i n s t a l l a t i o n s . Do n o t r e c e s s i n t o t h e t o p o f t h e
c h i m n e y .
1.
Mark each end of one flex liner with “
Ai r In t a k e
”.
2.
Mark each end of the second flex liner with “
Ex h a u s t
”.
3.
Pull the liner through the chimney.
4.
Install the flashing.
5.
Seal and attach the flex liner marked “
Ai r In t a k e
” to the vent terminal pipe marked “
Ai r In t a k e
” as per terminal manufacturers
instruction.
DO NOT U SE SILIC ONE.
6.
Seal and attach the flex liner marked “
Ex h a u s t
” to the vent terminal pipe marked “
Ex h a u s t
” as per terminal manufacturers
instruction.
DO NOT U SE SILIC ONE.
7.
Seal and attach the end of the flex liner marked
“A i r In t a k e ”
to the collar marked “
Ai r In t a k e
” on the appliance with the collar
clamp provided with the unit.
DO NOT U SE SILIC ONE.
8.
Seal and attach the end of the flex liner marked “
Ex h a u s t
” to the collar marked “
Ex h a u s t
” on the appliance with the collar clamp
provided with the unit.
DO NOT U SE SILIC ONE.
9.
Caulk all joints using a high temperature sealant such as milpac.
DO NOT U SE SILIC ONE. U s e o f s i l i c o n e s e a l a n t s v o i d s t h e
w a r r a n t y o f t h e p i l o t a s s e m b l y
.
NOTE:
The flex liners must form a complete connection from the appliance flue collars to the vertical termination cap.
The minimum flue (chimney) size required to run the two 3" (76 mm) is 4" x 7" (100 mm x 178 mm).
Fi g u r e 13. 3. 01:
Air Intake
Collar
Exhaust Collar
Exhaust
Fresh Air
Intake