13. 2 Ap p r o v e d Te r m i n a t i o n s
Ar c h g a r d Ve n t i n g C o m p o n e n t s
Ve n t C o m p o n e n t
Pa r t Nu m b e r
Vertical Termination
999-INS-TK
3" x 30' Aluminum Flex Liner
999-INS-FL330
3" x 50' Aluminum Flex Liner
999-INS-FL350
Approved venting components from third party manufacturers may be
found on the following page.
13. 1 Ex h a u s t Re s t r i c t o r
This appliance includes two exhaust restrictors in the manual bag.
These restrictors may be required if the vent length exceeds 20'
(6.1 M).
Ve n t l e n g t h
10' to 20' (3.05 M to 6.1 M)
No restrictor required
20' to 30' (6.1 M to 9.1 M)
Use one restrictor
30' to 40' (9.1 M to 12.2 M)
Use two restrictors
One restrictor (20 to 30 (6.1 M to 9.1 M)
i n s t a l l e d i n t h e c e n t e r .
Two restrictors (30 to 40 (9.1 M to 12.2 M)
i n s t a l l e d a t e a c h s i d e .
Fi g u r e 13. 1. 01:
Fi g u r e 13. 1. 02: